RIGOL DS1054Z

RIGOL DS1054Z Digital Oscilloscope User Manual

Model: DS1054Z

1. መግቢያ

The RIGOL DS1054Z is a 4-channel digital oscilloscope offering a 50MHz bandwidth, 1GSa/s real-time sampling rate, and a 24Mpt record length. It incorporates RIGOL's innovative UltraVision technology to provide advanced display and analysis capabilities. This manual provides essential information for the proper setup, operation, and maintenance of your DS1054Z oscilloscope.

2. ቁልፍ ባህሪያት

  • 50 MHz bandwidth with 4 analog channels.
  • Up to 1 GSa/s real-time sampየሊንግ ተመን።
  • Standard 12 Mpts memory depth, upgradeable to 24 Mpts.
  • Innovative UltraVision technology for enhanced signal visibility.
  • Waveform capture rate up to 30,000 wfms/s.
  • 7-inch WVGA (800x480) display with multi-level intensity grading.
  • All-in-one signal debugging and emulation.
  • Accelerated analysis and debugging for I2C, RS232, and SPI designs.

3. ምርት አብቅቷልview

This section provides a visual and functional overview of the RIGOL DS1054Z Digital Oscilloscope.

RIGOL DS1054Z Digital Oscilloscope front view

ምስል 1: የፊት view of the RIGOL DS1054Z Digital Oscilloscope, showing the display, control panel, and input channels.

RIGOL DS1054Z Digital Oscilloscope rear view

ምስል 2: የኋላ view of the RIGOL DS1054Z Digital Oscilloscope, displaying power input, USB, LAN, and auxiliary output ports.

4. ማዋቀር

  1. ማሸግ፡ Carefully remove the oscilloscope and all accessories from the packaging. Verify that all included components (power cord, USB cable, 4x 150MHz probes) are present.
  2. የኃይል ግንኙነት; Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable AC power outlet (100 V~240 V).
  3. አብራ፡ Press the power button located on the front panel to turn on the device. The display will illuminate, and the system will initiate its startup sequence.
  4. የመርማሪ ግንኙነት፡- Connect the 150MHz probes to the desired input channels (CH1-CH4) on the front panel. Ensure a secure connection.
  5. Initial Probe Compensation: Before taking measurements, it is recommended to perform probe compensation to ensure accurate readings. Refer to the detailed user guide for specific instructions on probe compensation.

5. የአሠራር መመሪያዎች

This section covers basic operational procedures for the DS1054Z oscilloscope.

5.1 መሰረታዊ የሞገድ ቅርፅ ማግኛ

  1. Connect Signal: Connect the probe to the signal source you wish to measure.
  2. ቻናል ይምረጡ፡- Press the corresponding channel button (e.g., CH1) to enable the channel.
  3. ራስ-ሰር ማዋቀር; For a quick display of the waveform, press the አውቶማቲክ button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings.
  4. በእጅ ማስተካከያ; Use the vertical scale (V/div) and position knobs for each channel, and the horizontal scale (s/div) and position knobs to fine-tune the waveform display.

5.2 Trigger Functions

The DS1054Z offers various trigger types to stabilize and capture specific events.

  • Edge Trigger: Triggers on a rising or falling edge of a signal.
  • Pulse Width Trigger: Triggers on pulses of a specified width.
  • Slope Trigger: Triggers on signals with a specific rise or fall time.
  • Video Trigger: Triggers on standard video signals.
  • Pattern Trigger: Triggers when a specific logic pattern is met across multiple channels.
  • Duration Trigger: Triggers on events lasting a specified duration.

To access trigger settings, press the TRIGGER MENU button and use the soft keys and multi-function knob to configure the desired trigger type and parameters.

Oscilloscope screen showing expanded functions and trigger settings

Figure 3: Oscilloscope display illustrating various expanded functions and trigger options, including memory depth settings.

5.3 Waveform Record and Playback

The DS1054Z allows for recording and playback of waveforms, which is useful for capturing transient events or analyzing long signal sequences.

  1. Access Record Function: Navigate to the waveform record menu (refer to the full user manual for exact menu path).
  2. Configure Recording: Set the desired record length and other parameters.
  3. መቅዳት ጀምር/አቁም፡ Initiate recording to capture waveforms. Stop recording when the desired data is acquired.
  4. መልሶ ማጫወት፡ እንደገና ለማጫወት የመልሶ ማጫወት መቆጣጠሪያዎችን ይጠቀሙview the recorded waveforms.
Oscilloscope screen showing waveform record and playback interface

Figure 4: Oscilloscope display showing the interface for waveform recording and playback, including controls for starting, stopping, and reviewየተቀረጸ ውሂብን ማስገባት።

6. ዝርዝሮች

መለኪያዝርዝር መግለጫ
አናሎግ ባንድዊድዝ50 ሜኸ
ቻናሎች4 አናሎግ ቻናሎች
Max. Real-time Sampደረጃ ይስጡ1 GSa/s (1 channel), 500 MSa/s (2 channels), 250 MSa/s (3/4 channels)
ከፍተኛ የማህደረ ትውስታ ጥልቀት12 Mpts (1 channel), 6 Mpts (2 channels), 3 Mpts (3/4 channels); upgradeable
Max. Waveform Capture Rate30,000 wfms/s
Vertical Input Impedance1 MΩ ± 2%
Vertical Input Range1 mV/div ወደ 10V/div
Horizontal Time Base Rangeከ5 ns/div ወደ 50 s/div
Standard Trigger FunctionsEdge, Pulse Width, Slope, Video, Pattern, Duration
Standard Bus DecodeParallel Bus
በይነገጾችUSB Host & Device, LAN (LXI), AUX Output (Trigger Out, Pass/Fail)
ማሳያ7.0-inch WVGA (800x480) TFT LCD, 64 intensity grading levels
የኃይል አቅርቦትAC: 100 V~240 V
ልኬቶች (WxHxD)313.1 ሚሜ x 160.8 ሚሜ x 122.4 ሚሜ
ክብደትበግምት. 3.2 ኪ.ግ
የተካተቱ መለዋወጫዎችPower cord, USB cable, 4x 150MHz probes

7. ጥገና

  • ማጽዳት፡ Regularly clean the exterior of the oscilloscope with a soft, dry cloth. For stubborn dirt, use a cloth lightly dampened with water or a mild, non-abrasive cleaner. Avoid using harsh chemicals or solvents.
  • የአየር ማናፈሻ; Ensure that the ventilation openings on the device are not obstructed to prevent overheating.
  • ማከማቻ፡ When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures.
  • የመርማሪ እንክብካቤ፡- Handle probes carefully. Avoid bending or stressing the cables excessively. Store probes properly to prevent damage to the tips and connectors.

8. መላ መፈለግ

This section addresses common issues you might encounter with your oscilloscope.

8.1 No Display After Power On

  • Check if the power cord is securely connected to both the oscilloscope and the power outlet.
  • የኃይል ማከፋፈያው የሚሰራ መሆኑን ያረጋግጡ.
  • የኃይል ቁልፉ ሙሉ በሙሉ መጫኑን ያረጋግጡ።

8.2 Unstable Waveform

  • የቀስቅሴውን ደረጃ በሞገድ ቅርጽ ላይ ወደ የተረጋጋ ነጥብ ያስተካክሉ።
  • Select an appropriate trigger type for the signal being measured (e.g., Edge trigger for periodic signals).
  • Check the probe connection and ensure it is properly compensated.
  • Verify the input signal's amplitude and frequency are within the oscilloscope's specifications.

8.3 No Signal Displayed

  • Ensure the input channel is enabled (its corresponding button is lit).
  • Check the probe connection to the signal source and the oscilloscope.
  • Adjust the vertical scale (V/div) to a more sensitive setting.
  • የሚለውን ይጫኑ አውቶማቲክ button to allow the oscilloscope to automatically find the signal.

9. ዋስትና እና ድጋፍ

9.1 የዋስትና መረጃ

The RIGOL DS1054Z main unit comes with a standard የ 3 ዓመት ዋስትና from the date of purchase when bought through Amazon. Accessories such as modules, probes, and batteries are covered by a የ 1 ዓመት ዋስትና. This warranty covers operational defects confirmed by RIGOL Japan. Parallel import products are not eligible for warranty or free support from RIGOL Japan.

In case of a suspected malfunction, after our company confirms that the event is a malfunction, we will provide a replacement with the same product or repair service, or other appropriate response as determined by our company.

9.2 Initial Defect Exchange Policy

Returns are accepted within 14 days of product arrival for initial defects. Return shipping costs for reasons other than operational defects are borne by the purchaser. Questions regarding operational defects or usage are accepted via Amazon email.

9.3 ጥገና እና ማስተካከል

For repair or calibration services, please contact a domestic authorized RIGOL dealer.

9.4 ተጨማሪ ግብዓቶች እና ድጋፍ

User guides, datasheets, and software for the DS1054Z can be downloaded from the official RIGOL Japan website. If you require an instruction manual earlier, please contact us via Amazon message.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.