EVURU DDS662

EVURU Digital Single Phase Energy Meter Instruction Manual

Models: DDS662, DDS667, DDS668

1. መግቢያ

This manual provides detailed instructions for the installation, operation, and maintenance of the EVURU Digital Single Phase Energy Meter. This device is designed to measure active energy (kWh), voltage, current, and power consumption in single-phase AC circuits. Please read this manual thoroughly before installation and use to ensure safe and correct operation.

2. የደህንነት መረጃ

  • ተከላ እና ጥገና መደረግ ያለበት ብቃት ባላቸው ባለሙያዎች ብቻ ነው.
  • ከማንኛዉም የመትከያ ወይም የሽቦ ሥራ በፊት የኃይል አቅርቦቱ መቋረጡን ያረጋግጡ።
  • Do not operate the meter in environments with excessive moisture, dust, or corrosive gases.
  • Verify all connections are secure and correct according to the wiring diagrams to prevent damage to the meter or electrical system.
  • The meter is designed for indoor use only.

3. ምርት አብቅቷልview እና ባህሪያት

The EVURU Digital Single Phase Energy Meter is a compact device for DIN rail installation, offering precise measurement of electrical parameters. Key features include:

  • LCD display with backlight for clear readings.
  • Measures total Energy (kWh), temporary Energy (kWh), real Voltage (V), real Current (A), and real Power (W).
  • Pulse LED indicator for active energy measurement.
  • 35mm DIN rail mounting.
  • Temporary kWh can be reset to zero. Total kWh is non-resettable.
Three EVURU digital energy meters: DDS662, DDS667, and DDS668, showing their front panels and LCD displays.

ምስል 1 - ተጠናቀቀview of DDS662, DDS667, and DDS668 models.

Comparison table showing features of DDS662, DDS667, and DDS668 models, including LCD display, electricity consumption, voltage, power, current, backlight, temporary power, manual switching, power factor, frequency, and zeroable function.

Figure 2: Feature comparison table for DDS662, DDS667, and DDS668 models.

4. ዝርዝሮች

መለኪያዋጋ
ከፍተኛው የአሁኑ80 ኤ
የልብ ምት ድግግሞሽ1000imp / kWh
በስመ ጥራዝtage220 ቪ ኤሲ
መጫን35 ሚሜ የዲን ባቡር
የማሳያ ዓይነትኤልሲዲ ከጀርባ ብርሃን ጋር
የሚለኩ መለኪያዎችTotal kWh, Temporary kWh, Voltagሠ, የአሁኑ, ኃይል
Temporary kWh ResetYes (hold button for 6 seconds)
Total kWh Resetአይ
Wiring ModesUpper input lower output, Lower input upper output
የእቃው ክብደት0.035 አውንስ (በግምት 1 ግራም)

5. መጫኛ (ማዋቀር)

5.1 ልኬቶች

Before installation, ensure adequate space for the meter. The dimensions are suitable for standard DIN rail enclosures.

Diagram showing the dimensions of the energy meter: 36mm width, 43mm height from base to top of display, 66mm total height including DIN rail clip, and 79mm depth.

Figure 3: Meter dimensions (example shown for DDS668).

5.2 DIN የባቡር ማፈናጠጥ

The meter is designed for 35mm DIN rail installation. Simply clip the meter onto the DIN rail in your electrical panel.

5.3 የወልና ንድፎችን

Ensure all power is OFF before proceeding with wiring. Connect the meter according to the appropriate diagram for your model and desired wiring mode.

5.3.1 DDS662 Wiring

The DDS662 model typically uses a direct connection for single-phase two-wire systems.

Wiring diagram for DDS662 energy meter showing Line (L) and Neutral (N) connections. Input L and N are at the top terminals, and output L and N are at the bottom terminals, indicating a direct pass-through connection.

Figure 4: Wiring diagram for DDS662 model.

5.3.2 DDS667 Wiring

The DDS667 model can be integrated with circuit breakers for protection.

Wiring diagram for DDS667 energy meter showing connection with two circuit breakers. The meter is connected between the load and the main power supply, with Line (L) and Neutral (N) inputs and outputs clearly marked.

Figure 5: Wiring diagram for DDS667 model, showing integration with circuit breakers.

5.3.3 DDS668 Wiring Modes

The DDS668 model supports two wiring configurations: upper input/lower output and lower input/upper output.

Two wiring diagrams for DDS668 energy meter. The left diagram shows upper input (N, L) and lower output (N, L). The right diagram shows lower input (N, L) and upper output (N, L), illustrating flexible wiring options.

Figure 6: Wiring diagrams for DDS668 model, illustrating upper input/lower output and lower input/upper output modes.

6. ኦፕሬሽን

6.1 በርቷል

Once correctly wired and mounted, restore power to the circuit. The LCD display will illuminate, showing the current readings.

6.2 Reading Displayed Values

The meter cycles through various parameters on its LCD display. You can manually press the button (if available on your model, e.g., DDS667, DDS668) to cycle through:

  • ጠቅላላ ኢነርጂ (kWh)
  • Temporary Energy (kWh)
  • Real Voltagሠ (ቪ)
  • Real Current (A)
  • እውነተኛ ኃይል (ወ)

The pulse LED will flash to indicate active energy measurement.

6.3 Resetting Temporary kWh

To reset the temporary kWh reading to zero, press and hold the button on the front of the meter for approximately 6 seconds. Note that the total kWh reading cannot be reset.

7. ጥገና

The EVURU Digital Single Phase Energy Meter requires minimal maintenance.

  • Keep the meter clean and free from dust. Use a soft, dry cloth for cleaning.
  • ገላጭ ማጽጃዎችን ወይም ፈሳሾችን አይጠቀሙ.
  • የሽቦ ግንኙነቶችን ጥብቅነት እና የመበስበስ ወይም የመጎዳት ምልክቶችን በየጊዜው ይመርምሩ።
  • Ensure the operating environment remains within specified conditions (temperature, humidity).

8. መላ መፈለግ

  • No Display / Meter Not Powering On:
    • የወረዳውን የኃይል አቅርቦት ይፈትሹ።
    • Verify all wiring connections are secure and correct according to the diagrams.
  • የተሳሳቱ ንባቦች፡-
    • Ensure the meter is correctly wired for the load. Incorrect wiring can lead to inaccurate measurements.
    • ጥራዝ አረጋግጥtage and current are within the meter's specified range (e.g., 220V AC, max 80A).
  • Temporary kWh Not Resetting:
    • Ensure you are holding the reset button for the full 6 seconds.
    • Note that the total kWh cannot be reset.
  • Pulse LED Not Flashing:
    • Verify there is an active load connected and drawing power through the meter.
    • Check wiring for proper current flow.

9. ዋስትና እና ድጋፍ

የዋስትና መረጃ ወይም የቴክኒክ ድጋፍ ለማግኘት፣ እባክዎን የምርት ማሸጊያውን ይመልከቱ ወይም ቸርቻሪዎን ያነጋግሩ። የግዢ ደረሰኝዎን እንደ ግዢ ማረጋገጫ ያስቀምጡ።

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.