1. መግቢያ
This manual provides comprehensive instructions for the installation, setup, operation, and maintenance of the UOFKIPBA WINPARK AK6 PID Temperature Controller, model AK6-BKL110. This device is designed for precise temperature control in various industrial and laboratory applications. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.
2. የደህንነት መረጃ
በመሳሪያው ላይ ጉዳት ወይም ጉዳት እንዳይደርስ ለመከላከል ሁል ጊዜ የሚከተሉትን የደህንነት ጥንቃቄዎች ይከተሉ።
- ሁሉም ሽቦዎች በሰለጠኑ ሰራተኞች መከናወናቸውን እና ከአካባቢው የኤሌክትሪክ ኮዶች ጋር የሚጣጣሙ መሆናቸውን ያረጋግጡ።
- Disconnect power before performing any installation, wiring, or maintenance.
- Do not operate the controller in environments with flammable gases, vapors, or excessive dust.
- ትክክለኛውን ጥራዝ ያረጋግጡtagኃይልን ከማገናኘትዎ በፊት ኢ እና የአሁኑ ደረጃዎች።
- Avoid exposing the controller to direct sunlight, high humidity, or extreme temperatures.
- መሳሪያውን እራስዎ ለመጠገን ወይም ለመለወጥ አይሞክሩ. ብቃት ያላቸውን የአገልግሎት ሰራተኞች ያነጋግሩ።
3. ምርት አብቅቷልview
The UOFKIPBA WINPARK AK6 PID Temperature Controller is a compact and reliable device for accurate temperature regulation. It features a clear digital display for process value (PV) and set value (SV), along with indicator lights for output and alarm status. The controller supports various input types and offers multiple control outputs.
3.1 የፊት እና የጎን View

3.2 Rear Terminal Connections

4. መጫን
4.1 መጫን
The AK6 controller is designed for panel mounting. Ensure the panel cutout dimensions are 48x96mm. Secure the controller using the provided mounting brackets.
- Cut a rectangular opening of 48mm x 96mm in the mounting panel.
- Insert the controller into the opening from the front.
- Attach the mounting brackets to the sides of the controller from the rear of the panel and tighten the screws to secure it firmly.
4.2 ሽቦ
Refer to the wiring diagram on the side of the controller (Figure 1) and the rear terminal block (Figure 2) for correct connections. Ensure all connections are secure and insulated.
- የኃይል አቅርቦት (ኤሲ)፡- Connect the AC power supply to terminals 8 and 9. Verify the voltage matches the controller's specifications.
- SSR Output 1 (OUT1/ALM1): Connect the Solid State Relay (SSR) control input for the primary output to terminals 10 and 11.
- SSR Output 2 (OUT2/ALM2): Connect the SSR control input for the secondary output or alarm 2 to terminals 12 and 13.
- Temperature Sensor Input (TEMP): Connect your temperature sensor (e.g., thermocouple, RTD) to terminals 14 (V-) and 15 (V+). Ensure correct polarity for thermocouples.
- Alarm Output (ALM1/ALM2): If using relay alarms, connect to the appropriate terminals as indicated on the wiring diagram.
ማስታወሻ፡- The specific terminal assignments may vary slightly depending on the exact model variant (e.g., relay output vs. SSR output). Always consult the diagram printed on your specific unit.
5. የመጀመሪያ ደረጃ ማዋቀር እና ማዋቀር
After successful installation and wiring, power on the controller. The display will show the current Process Value (PV) and Set Value (SV).
5.1 Setting the Set Value (SV)
- የሚለውን ይጫኑ አዘጋጅ button once. The SV display will begin to flash.
- የሚለውን ተጠቀም ወደ ላይ (▲) እና ወደታች (▼) arrow buttons to adjust the desired set temperature.
- ተጫን አዘጋጅ again to confirm the new SV and exit the setting mode.
5.2 Accessing Parameter Settings
To access advanced parameters (e.g., input type, control mode, PID parameters), press and hold the አዘጋጅ button for approximately 3-5 seconds until the first parameter code appears on the PV display.
- የሚለውን ተጠቀም አዘጋጅ button to cycle through different parameters.
- የሚለውን ተጠቀም ወደ ላይ (▲) እና ወደታች (▼) arrow buttons to change the value of the currently displayed parameter.
- To save changes and exit, stop pressing buttons for several seconds, or cycle through all parameters until the controller returns to normal operation.
ማስታወሻ፡- Consult the detailed parameter list (usually provided in a separate sheet or advanced manual) for specific parameter codes and their functions. Incorrect parameter settings can lead to unstable control or damage.
6. የአሠራር መመሪያዎች
6.1 Auto-Tuning (AT) Function
The auto-tuning function helps the controller automatically determine optimal PID parameters for your specific system, ensuring stable and accurate temperature control.
- Set your desired Set Value (SV).
- ተጭነው ይያዙት። AT button for approximately 3-5 seconds. The AT indicator light will illuminate, indicating auto-tuning is in progress.
- During auto-tuning, the system temperature will cycle around the SV. Allow the process to complete without interruption.
- Once auto-tuning is finished, the AT indicator will turn off, and the controller will operate with the newly calculated PID parameters.
ጥንቃቄ፡- Auto-tuning may cause temporary temperature fluctuations. Ensure this is acceptable for your application before initiating.
6.2 Manual Control (MAN)
In some cases, manual control of the output power may be desired.
- የሚለውን ይጫኑ ሰው button to switch to manual control mode. The ሰው አመላካች ያበራል።
- የሚለውን ተጠቀም ወደ ላይ (▲) እና ወደታች (▼) arrow buttons to adjust the output power percentage.
- ተጫን ሰው again to exit manual mode and return to automatic control.
7. ጥገና
Regular maintenance ensures the longevity and optimal performance of your temperature controller.
- ማጽዳት፡ የፊት ፓነሉን በየጊዜው ለስላሳና ደረቅ ጨርቅ ያጽዱ። ሻካራ ማጽጃዎችን ወይም ሟሟቶችን አይጠቀሙ።
- ምርመራ፡- Regularly check wiring connections for looseness or signs of damage. Ensure the controller's ventilation slots are not obstructed.
- አካባቢ፡ Maintain the operating environment within the specified temperature and humidity ranges.
8. መላ መፈለግ
ይህ ክፍል ሊያጋጥሙህ ለሚችሉ የተለመዱ ጉዳዮች መፍትሄዎችን ይሰጣል።
| ችግር | ሊሆን የሚችል ምክንያት | መፍትሄ |
|---|---|---|
| ተቆጣጣሪው አይበራም። | የኃይል አቅርቦት የለም፤ የተሳሳተ ሽቦ፤ የተነፈሰ ፊውዝ። | Check power connections (terminals 8 & 9). Verify power source. Inspect internal fuse if accessible (consult service). |
| PV display shows "HHHH" or "LLLL". | Sensor open circuit; sensor short circuit; incorrect sensor type setting. | Check sensor wiring (terminals 14 & 15). Replace faulty sensor. Verify sensor type in parameter settings. |
| Temperature control is unstable or oscillates. | Incorrect PID parameters; system disturbance. | Perform auto-tuning (Section 6.1). Check for external factors affecting temperature stability. |
| Output does not activate. | Output wiring error; output type mismatch; controller in manual mode with 0% output. | Verify output wiring (terminals 10-13). Check output type setting in parameters. Ensure controller is in auto mode or manual output is set above 0%. |
9. ዝርዝሮች
Key technical specifications for the UOFKIPBA WINPARK AK6 PID Temperature Controller (AK6-BKL110):
- ሞዴል፡ AK6-BKL110
- መጠኖች፡- 48x96mm (Panel Cutout)
- የጥቅል መጠኖች: 11.81 x 7.87 x 3.94 ኢንች
- የእቃው ክብደት፡ 1.76 አውንስ
- አምራች፡ UOFKIPBA
- የመቆጣጠሪያ ዘዴ፡- PID (Proportional-Integral-Derivative)
- የውጤት አይነት፡ SSR (Solid State Relay)
- የግቤት አይነት: Universal (e.g., K, J, E, T, R, S, B, Pt100, Cu50) - Specific input type must be configured.
- የኃይል አቅርቦት; AC (Voltage range typically 85-265V AC, refer to unit label)
- ማሳያ፡- Dual 4-digit LED (PV & SV)
10. ዋስትና እና ድጋፍ
For warranty information and technical support, please refer to the documentation provided with your purchase or contact your vendor. Keep your purchase receipt as proof of purchase.