AOLON W3002 Microcomputer Temperature Controller

ቴክኒካዊ ዝርዝሮች
| ዝርዝር መግለጫ | ዝርዝሮች |
|---|---|
| የምርት ስም | Microcomputer Temperature Controller (XH-W3002) |
| የመለኪያ ክልል | -50°C to 110°C (-50°C to 100°C model variation) |
| የመቆጣጠሪያ ክልል | -50°C to 110°C (-50°C to 100°C model variation) |
| የሙቀት መለኪያ ትክክለኛነት | ± 0.2 ° ሴ |
| የሙቀት መቆጣጠሪያ ትክክለኛነት | ± 0.1 ° ሴ |
| የመለኪያ ግቤት | NTC10K L=1m waterproof probe |
| Input Power Options | 12V / 24V / 220V AC/DC |
| የውጤት ኃይል አማራጮች | 120W (12V) / 240W (24V) / 1500W (220V) |
| የውጤት አይነት | ቀጥተኛ ውፅዓት |
| የውጤት አቅም | ከፍተኛው 10 ኤ |
| የመጫኛ ቀዳዳ ርቀት | 73mm (Hole size: 4mm) |
| መጠኖች | 60 ሚሜ × 45 ሚሜ × 31 ሚሜ |
ፈጣን ቅንብር እና አጠቃቀም
- Connect the temperature sensor: use the supplied NTC10K waterproof probe (L=1m).
- Provide power using one supported option: 12V/24V/220V AC/DC.
- Set start temperature (P0): press the በማቀናበር ላይ button to enter the menu (default to P0), press በማቀናበር ላይ again, then use Up/ወደታች to set the desired start temperature.
- Set stop temperature (P1): in the menu, use Up/ወደታች to select P1, press በማቀናበር ላይ again, then adjust with Up/ወደታች.
- (Optional) Calibrate temperature (P2): select P2, press በማቀናበር ላይ to enter calibration, then set the offset value using Up/ወደታች.
- (Optional) Set delayed start (P3): select P3 and set the delay time (minutes) using Up/ወደታች (recommended 3–6 minutes for compressor-based refrigeration; otherwise leave at 0).
Wiring Diagrams & Safety Information
12V / 24V Connection Way
ማሳሰቢያ፡- 12V/24V power supplies must use a stable DC power source.
220V Connection Way
ማስጠንቀቂያ፡- This model is designed with direct output power. Exercise extreme caution when connecting the electricity. Ensure the load is connected to the output terminal port before powering up to prevent potential output short circuit ignition or sparks.
Settings Parameter Menu
| ኮድ | መግለጫ | ክልልን በማቀናበር ላይ | የፋብሪካ ነባሪ |
|---|---|---|---|
| P0 | የመነሻ ሙቀት | -50 እስከ 110 ° ሴ | 00 ° ሴ |
| P1 | የሙቀት መጠንን አቁም | -50 እስከ 110 ° ሴ | 00 ° ሴ |
| P2 | የሙቀት ማስተካከያ | -10 እስከ 10 ° ሴ | 0 ° ሴ |
| P3 | Delay to start | ከ 0 እስከ 10 ደቂቃዎች | 0 ደቂቃዎች |
Parameter Configurations & Functions
P0: Start-up Temperature Setting
የሚለውን ይጫኑ በማቀናበር ላይ button to enter the internal menu. The display will default to P0. የሚለውን ይጫኑ በማቀናበር ላይ button once more, then use the Up እና ወደታች buttons to set your desired start temperature.
የሚለውን ይጫኑ በማቀናበር ላይ button to enter the internal menu. When
P0 is displayed, use the Up or ወደታች ለመምረጥ አዝራሮች P1. የሚለውን ይጫኑ በማቀናበር ላይ button again, and adjust the target stop temperature using the Up እና ወደታች አዝራሮች.የሚለውን ይጫኑ በማቀናበር ላይ button to enter the internal menu, then switch to
P2 በመጠቀም Up or ወደታች አዝራሮች. የሚለውን ይጫኑ በማቀናበር ላይ button again to calibrate. Use the Up እና ወደታች buttons to enter the offset value.Calibration Formula: Detected Temperature + Calibration Temperature = Actual Temperature
- If the detected temperature is 0.5°C higher than the actual temperature: Set P2 to -0.5 ° ሴ
- If the detected temperature is 1.0°C lower than the actual temperature: Set P2 to 1.0 ° ሴ
P3: Delayed Start Setting
የሚለውን ይጫኑ በማቀናበር ላይ button to enter the internal menu and switch to P3 በመጠቀም Up or ወደታች አዝራሮች. የሚለውን ይጫኑ በማቀናበር ላይ button again and set the delay time in minutes using the Up or ወደታች አዝራሮች.
ማስታወሻ፡- This function is typically used for compressor-based refrigeration systems (like refrigerators or freezers) to protect the motor. A delay of 3 to 6 minutes is recommended. If you are not controlling a compressor, leave this set to 0.
የክወና ሁነታዎች
የማሞቂያ ሁነታደንብ፡-Start-up Temperature (P0) < Stop Temperature (P1) The system automatically determines it is in heating mode when P0 is configured lower than P1.
Exampለ ሁኔታ፡-
Control a water heater to turn off when the temperature reaches 50°C and restart heating when the temperature drops back down to 40°C.
- Verify that the heating rule is met: Start-up (40°C) is less than Stop (50°C).
- የሚለውን ይጫኑ በማቀናበር ላይ button, enter the menu, select
P0, and adjust the value to 40 ° ሴ. - የሚለውን ይጫኑ በማቀናበር ላይ button, enter the menu, select
P1, and adjust the value to 50 ° ሴ.
የማቀዝቀዣ ሁነታደንብ፡- Start-up Temperature (pø) > Stop Temperature (Pl). The system automatically determines it is in cooling mode when P0 is configured higher than P1.
Exampለ ሁኔታ፡-
Control a cabinet radiator to turn on when temperatures reach 30°C and stop cooling once the temperature drops to 26°C.
- Verify that the cooling rule is met: Start-up (30°C) is greater than Stop (26°C).
- የሚለውን ይጫኑ በማቀናበር ላይ button, enter the menu, select
P0, and adjust the value to 30 ° ሴ. - የሚለውን ይጫኑ በማቀናበር ላይ button, enter the menu, select
P1, and adjust the value to 26 ° ሴ.
መላ መፈለግ
Common Fault: Incorrect Settings
If you set your temperature values upside down (e.g., configuring heating parameters with P0 > P1), the output indicator light will remain off and the connected load will not work. Check the temperature values in your P0 እና P1 settings if the system is unresponsive.
With the controller powered on, press and hold both the Up እና ወደታች buttons simultaneously for approximately 3 seconds. Once the digital tube displays
888, The controller will automatically return to real-time temperature detection, indicating a successful factory reset.- Display “LLL”: Indicates a temperature sensor probe failure. Please inspect, repair, or replace the waterproof probe.
- Display “HHH”: Indicates that the ambient temperature has exceeded the controller’s detection range. Relocate the unit to an appropriate environment.