Intercomp 100058 Valve Spring Tester User Manual

ሞዴል፡ 100058

መግቢያ

This manual provides instructions for the safe and effective operation of the Intercomp 100058 Valve Spring Tester. This device is designed for accurately measuring the force of valve, clutch, shock, and pressure relief springs up to 2 inches (50mm) in diameter. It features a portable digital force and travel indication with a peak hold function, ensuring precise measurements for various automotive and mechanical applications.

አስፈላጊ የደህንነት መመሪያዎች

ማዋቀር

Initial Setup Procedures

  1. ማሸግ፡ Carefully remove the Valve Spring Tester from its packaging. Inspect the unit for any visible signs of damage that may have occurred during shipping.
  2. የባትሪ ጭነት; The device operates on a standard 9-volt battery. Locate the battery compartment, typically on the back or side of the unit. Insert a fresh 9-volt battery, ensuring correct polarity.
  3. አቀማመጥ፡- Place the tester on a sturdy, flat, and stable workbench or surface that can support its weight and the forces applied during testing.
  4. አብራ፡ Press the designated power button to turn on the device. The backlit digital display should illuminate, indicating the unit is ready for use.

Intercomp 100058 Valve Spring Tester with digital display and compression mechanismImage: The Intercomp 100058 Valve Spring Tester showing its digital display and the spring compression platform. This image illustrates the overall design and key components of the device, including the handle and base.

የአሠራር መመሪያዎች

Measuring Spring Force

  1. ማሳያውን ዜሮ ማድረግ፦ Before placing any spring on the tester, ensure the digital display reads zero. If it does not, press the 'ZERO' or 'TARE' button (if available) to reset the reading.
  2. Positioning the Spring: Carefully place the spring to be tested onto the lower platform of the tester. Ensure it is centered and stable to prevent it from slipping during compression. The tester accommodates springs up to 2 inches (50mm) in diameter.
  3. Compressing the Spring: Use the compression mechanism (e.g., a hand crank or lever) to slowly and steadily compress the spring. Observe the digital display for the real-time force reading.
  4. Reading Peak Hold: The Intercomp 100058 features a peak hold function. This function automatically captures and displays the maximum force reading achieved during the compression cycle. This is particularly useful for springs that may be compressed quickly.
  5. መልቀቅasing the Spring: Once the desired measurement is obtained or the spring is fully compressed and released, slowly and carefully release the compression mechanism. Remove the spring from the platform.
  6. ብዙ ንባቦች፡- For optimal accuracy and consistency, it is recommended to perform several measurements for each spring and calculate an average of the results.

The digital display provides readings in precise 0.2 lb (or equivalent kg) increments, allowing for detailed analysis of spring characteristics.

ጥገና

Care and Storage Guidelines

መላ መፈለግ

የተለመዱ ጉዳዮች እና መፍትሄዎች

ችግርሊሆን የሚችል ምክንያትመፍትሄ
መሣሪያው አይበራም።የሞተ ወይም በስህተት የተጫነ ባትሪCheck battery polarity; replace with a fresh 9-volt battery.
ትክክለኛ ያልሆኑ ንባቦችDevice not zeroed; exceeding capacity; needs calibrationZero the display before each use. Ensure spring force is within the 1,000 lb capacity. Consider professional calibration if issues persist.
ማሳያው ደብዛዛ ወይም ብልጭ ድርግም የሚል ነው።ዝቅተኛ ባትሪReplace the 9-volt battery with a new one.
Spring slips during compressionImproper spring placement; spring diameter too large/smallEnsure the spring is centered and stable on the platform. Verify spring diameter is within the 2-inch (50mm) limit.

ዝርዝሮች

የቴክኒክ ውሂብ

For detailed specifications or further assistance, please contact Intercomp customer support.

ተዛማጅ ሰነዶች - 100058

ቅድመview Littelfuse 100/102/122 Series Cartridge Fuse Clips - Technical Specifications and Ordering Information
Detailed technical specifications, product dimensions, mounting dimensions, and ordering information for Littelfuse 100/102/122 Series low profile circuit board mount fuse clips designed for 1/4" diameter fuses.
ቅድመview Autosport Magazine - November 18, 2010: Vettel Crowned Champion
This document presents key pages from the November 18, 2010 issue of Autosport magazine, focusing on Sebastian Vettel's historic F1 championship win, Red Bull Racing's success, and comprehensive coverage of various motorsport events, services, and products.
ቅድመview Autosport መጽሔት ምደባዎች እና የክስተት ዝርዝሮች
ከAutosport መጽሔት የወጡ የማስታወቂያዎች እና የክስተት ዝርዝሮች ስብስብ፣የተለያዩ ተሽከርካሪዎችን፣ የሞተር ስፖርት ዜናዎችን እና አገልግሎቶችን፣ የRV ሽያጭን፣ የዘር መኪና ዝርዝሮችን እና web የማውጫ አገልግሎቶች.
ቅድመview LoRaWAN Certified Devices List
A comprehensive list of LoRaWAN certified devices, including company names, product names, certification dates, expiration dates, and regions, as provided by the LoRa Alliance.
ቅድመview Oferta Especial MESTRA: Equipamiento de Laboratorio Dental
Descubra las últimas ofertas especiales de MESTRA para laboratorios dentales. Este catálogo presenta una selección exclusiva de equipamiento de alta calidad con descuentos significativos en escáneres 3D, hornos de sinterización, unidades de anodizado y más. Optimice su laboratorio con tecnología de vanguardia.