Rectorseal PR-1L is a purple, low VOC, hi-etch primer specifically formulated for all PVC and CPVC pipe applications. This includes potable water, pressure pipe, gas, conduit, sewers, and drain, waste, and vent (DWV) systems. Its distinctive purple color provides a visual check for complete coverage, ensuring proper surface preparation for superior bonding strength. The primer is LEED Compliant, NSF approved for potable water systems, and meets ASTM F 656 specifications.

Rectorseal 55912 PR-1L Purple Low VOC Hi-Etch PVC and CPVC Primer can

Image 1.1: A can of Rectorseal 55912 PR-1L Purple Low VOC Hi-Etch PVC and CPVC Primer.

ቁልፍ ባህሪዎች

2. የደህንነት መረጃ

አደጋ፡ Highly Flammable. Vapors may cause flash fire. Harmful or fatal if swallowed. May cause severe eye and skin irritation.

ቅድመ ጥንቃቄዎች፥

የመጀመሪያ እርዳታ;

3. ዝግጅት

Proper preparation is crucial for a strong, leak-free joint. Follow these steps before applying the primer:

  1. የቧንቧ መቁረጥ; Cut the pipe square using a suitable pipe cutter.
  2. Deburr and Chamfer: Remove all burrs from the inside and outside edges of the pipe. Chamfer the end of the pipe to facilitate insertion into the fitting.
  3. የንጹህ ንጣፎች; Ensure all pipe and fitting surfaces are clean, dry, and free from dirt, grease, oil, and moisture. Use a clean, dry cloth to wipe surfaces.
  4. ደረቅ ተስማሚነት; Dry fit the pipe and fitting to ensure proper alignment and an interference fit. The pipe should enter the fitting socket easily by 1/3 to 2/3 of the socket depth.

4. የመተግበሪያ መመሪያዎች

Apply Rectorseal PR-1L primer and solvent cement according to the following procedure:

  1. Apply Primer to Pipe: Using a natural bristle brush or dauber, apply a liberal and uniform coat of PR-1L primer to the pipe surface, covering an area equal to the depth of the fitting socket. Ensure the entire surface is wetted and purple in color.
  2. Apply Primer to Fitting: Immediately apply a liberal and uniform coat of PR-1L primer to the inside of the fitting socket. Ensure complete coverage.
  3. የሟሟ ሲሚንቶ ይተግብሩ፤ While the primer is still wet (do not allow primer to dry), immediately apply the appropriate PVC or CPVC solvent cement to both the primed pipe end and the primed inside of the fitting socket. Follow the solvent cement manufacturer's instructions for application.
  4. Assemble Joint: Quickly insert the pipe into the fitting socket, twisting a quarter turn until the pipe bottoms out. Hold the joint together firmly for at least 30 seconds to ensure initial set and prevent the pipe from backing out.
  5. ከመጠን በላይ ማስወገድ; Wipe off any excess cement from the joint using a clean cloth.
  6. የፈውስ ጊዜ፡- Allow adequate cure time before handling or pressure testing the joint. Refer to the solvent cement manufacturer's recommendations for specific cure times, which vary based on pipe size, temperature, and humidity.

5. Cleanup and Storage

ማጽዳት፡

Clean tools and spills immediately with an appropriate solvent cleaner. Ensure proper ventilation during cleanup.

ማከማቻ፡

Store Rectorseal PR-1L primer in its original container, tightly closed, in a cool, dry, well-ventilated area. Keep away from direct sunlight, heat sources, sparks, and open flames. Do not store above 110°F (43°C). Ensure the container is sealed when not in use to prevent evaporation and maintain product effectiveness.

6. መላ መፈለግ

ጉዳይ ሊሆን የሚችል ምክንያት መፍትሄ
Poor Bond Strength Insufficient primer application or primer/cement applied to dirty/wet surfaces. Ensure complete and uniform coverage of primer. Thoroughly clean and dry surfaces before application.
Poor Bond Strength Insufficient cure time for solvent cement. Allow recommended cure time as specified by the solvent cement manufacturer.
Poor Bond Strength Primer or cement is expired or contaminated. Check product expiration dates. Ensure containers are sealed when not in use.
Primer Dries Too Quickly High ambient temperature or low humidity. Work in a cooler environment if possible. Apply primer and cement quickly.
Primer Dries Too Quickly Container left open. ጥቅም ላይ በማይውልበት ጊዜ መያዣውን በጥብቅ ይዝጉ።

7. ዝርዝሮች

ባህሪ ዝርዝር
የምርት ስም Rectorseal
የሞዴል ቁጥር 55912
የምርት ስም PR-1L Purple Low VOC Hi-Etch PVC and CPVC Primer
ቀለም ሐምራዊ
የማጠናቀቂያ ዓይነት ማት
መጠን 1/2 Pint (approx. 0.236 Liters)
ልዩ ባህሪያት Low VOC, Hi-Etch
ልዩ አጠቃቀሞች Plumbing and related systems (potable water, pressure pipe, gas, conduit, sewers, DWV)
የገጽታ ጥቆማ PVC, CPVC
የውሃ መቋቋም ደረጃ የውሃ መቋቋም
የምስክር ወረቀቶች LEED Compliant, NSF Approved for Potable Water Systems, Meets ASTM F 656
ዩፒሲ 021449559126
የእቃው ክብደት 8 አውንስ
የምርት ልኬቶች 17 x 12 x 5 ኢንች (የማሸጊያ ልኬቶች)

8. ዋስትና እና ድጋፍ

Rectorseal products are manufactured to high-quality standards. For specific warranty information or technical support, please contact Rectorseal directly or visit their official website. You can also find more information and browse other products at the Rectorseal Brand Store.

ተዛማጅ ሰነዶች - 55912

ቅድመview RectorSeal Falcon Thermal Expansion Tanks Installation Guide
Comprehensive installation guide for RectorSeal Falcon Thermal Expansion Tanks (2.1, 4.8, and 10.1 gallon models EXPT2, EXPT4, EXPT10). Includes critical safety warnings, product inspection, pre-charge adjustment procedures, installation steps, diagram explanation, warranty, and approvals for potable water systems.
ቅድመview RSH-50 የቀዶ ጥገና መከላከያ መሳሪያ መጫኛ መመሪያዎች እና ዋስትና
የመጫኛ መመሪያዎች እና የዋስትና መረጃ ለ RectorSeal RSH-50 Surge Protection Device ከማይቀላቀል አቋርጥ ሳጥን 120/240 VAC, 60A. የምርት ዝርዝሮችን፣ የወልና ንድፎችን፣ የደህንነት ማስታወቂያዎችን እና የዋስትና ሽፋንን ያካትታል።
ቅድመview Rectorseal No. 5 ፕሪሚየም ባለብዙ-ዓላማ የፓይፕ ክር ማሸጊያ የደህንነት መረጃ ወረቀት
የደህንነት መረጃ ሉህ ለ Rectorseal No.5፣ ፕሪሚየም ሁለገብ ዓላማ ያለው የቧንቧ ክር ማሸጊያ። ስለ አደጋዎች፣ የመጀመሪያ እርዳታ፣ አያያዝ፣ ማከማቻ እና አወጋገድ መረጃ ይሰጣል።
ቅድመview RectorSeal AquaGuard AG-1200+ Installation Instructions
Detailed installation instructions for the RectorSeal AquaGuard AG-1200+ magnetic float switch, including safety precautions, mounting, and wiring diagrams for conventional and communicating HVAC systems.
ቅድመview RectorSeal AG-9100 AquaGuard የርቀት ደወል መጫን እና የዋስትና መመሪያ
ለRectorSeal AG-9100 AquaGuard የርቀት ማንቂያ ስርዓት አጠቃላይ የመጫኛ መመሪያዎች ፣የገመድ ሥዕላዊ መግለጫዎች ፣የደህንነት መመሪያዎች እና የተገደበ የዋስትና መረጃ። የእርስዎን AG-9100 ማንቂያ በትክክል እንዴት እንደሚሰካ፣ ሽቦ እና እንደሚሞክር ይወቁ።
ቅድመview RectorSeal RSHVRM60A Installation and Safety Guide
Comprehensive installation, programming, and safety information for the RectorSeal RSHVRM60A 120/240 Single Phase, 60 Amp Double Pole Capacity Relay.