Lutron MS-OPS6M2-DV-GR

Lutron Maestro MS-OPS6M2-DV-GR Occupancy Sensing Switch Instruction Manual

Model: MS-OPS6M2-DV-GR | Brand: Lutron

1. መግቢያ

The Lutron Maestro Occupancy Sensing Switch is designed to automatically turn lights on and off based on room occupancy, providing convenience and energy savings. This switch supports multi-location control and is compatible with various lighting loads and general-purpose fans.

ቁልፍ ባህሪዎች

  • Multi-location, single pole or 3-way operation.
  • Supports up to 6-Amps for lighting (120 Volts or 277 Volts) and 3-Amps for fans.
  • Compatible with incandescent, halogen, magnetic and electronic low-voltage, non-dim LED, and non-dim fluorescent bulbs, as well as general purpose fans.
  • Automatic light control based on occupancy.
  • Requires a ground wire for installation.

2. ጠቃሚ የደህንነት መረጃ

WARNING: RISK OF ELECTRIC SHOCK. May result in serious injury or death. Turn off power at circuit breaker or fuse before installing. Ensure power is OFF before proceeding with installation.

  • በሁሉም ብሔራዊ እና አካባቢያዊ የኤሌክትሪክ ኮዶች መሠረት ይጫኑ ፡፡
  • This device must be installed by a qualified electrician if you are unsure about the wiring process.
  • Do not use with loads exceeding the specified ampእርጅና።
  • ለቤት ውስጥ አገልግሎት ብቻ.

3. የጥቅል ይዘቶች

Your package should include the Lutron Maestro Occupancy Sensing Switch and an instruction guide. Additional accessories like wall plates are sold separately.

ፊት ለፊት view of the Lutron Maestro Occupancy Sensing Switch in gray

ምስል 1: የፊት view of the Lutron Maestro Occupancy Sensing Switch in gray.

ተመለስ view of the Lutron Maestro Dual Voltage Sensor showing wiring points

ምስል 2፡ ተመለስ view of the Lutron Maestro Dual Voltage Sensor, highlighting wiring points and features like the tap switch and sensor LED.

4. መጫን

Before beginning, ensure power is turned OFF at the circuit breaker. Use a voltage tester to confirm the power is off before touching any wires.

4.1 Single-Pole Installation

  1. ኃይል ያጥፉ; Locate your circuit breaker and turn off the power to the switch you are replacing. Double-check with a voltagሠ ሞካሪ።
  2. ያለውን መቀየሪያ ያስወግዱ፡ Unscrew and carefully pull out the existing switch from the wall box.
  3. ሽቦዎችን መለየት፦ You should have two wires from the wall connected to your old switch, plus a ground wire. Identify if you have a neutral (typically white) or ground (bare copper or green) wire coming out of the wall box.
  4. Wire the new sensor:
    • If a neutral wire is available: Remove the green sleeve from the sensor's white wire and connect the sensor's white wire to the neutral wire from the wall. Connect the sensor's bare wire to the ground wire from the wall.
    • If no neutral wire is available: Leave the green sleeve on the sensor's white wire. Connect both the sensor's green wire (with sleeve) and the sensor's bare wire to the ground wire from the wall.
    • Connect one of the two wires from your wall to one of the black wires on your new sensor.
    • Connect the remaining wire from the wall to the other black wire on your sensor.
    • Place a wire cap on the blue wire from the sensor. This is not used in a single-pole application.
  5. Mount the sensor: Carefully push all wires back into the wall box and secure the sensor with screws.
  6. የግድግዳ ሰሌዳ መትከል፡ Attach your wall plate (sold separately).
  7. ኃይልን ወደነበረበት መመለስ; በወረዳው ተላላፊው ላይ ኃይሉን መልሰው ያብሩት።

Video 1: Installation guide for Lutron Maestro 5 Amp & 6 Amp Sensor Switch in a single-pole configuration. This video demonstrates the step-by-step process of replacing an existing switch with the Maestro sensor, including safety precautions, wire identification, and final mounting.

4.2 Multi-Location (3-Way) Installation

For multi-location setups (where two switches control the same light), you will install the Maestro sensor in one location and a Maestro companion switch (MA-AS or MSC-AS) or update an existing 3-way switch in the other location(s).

  1. ኃይል ያጥፉ; በወረዳው ላይ ያለውን ኃይል ያጥፉ።
  2. አሁን ያሉትን መቀየሪያዎች ያስወግዱ፦ Unscrew and carefully pull out the existing switches from both wall boxes.
  3. Identify wires at the Maestro sensor location: You should have three wires plus a ground connected to your old switch. Take a piece of electrical tape and tag the wire connected to the different colored screw of the existing switch (typically a black wire).
  4. Wire the Maestro sensor: Follow the neutral/ground wiring steps as in single-pole installation. Connect the tagged wire (from the different colored screw) to one of the black wires on your new sensor. Connect the remaining two wires from the wall to the remaining black wire and the blue wire on the sensor. Make a note of the color wire you connect to the blue wire, as this will be important for the second location.
  5. Mount the Maestro sensor: Secure the sensor in its wall box.
  6. Wire the second location (Companion Switch):
    • At the second location, identify the common wire (the one connected to the different colored screw on the old switch). Attach this common wire to the black screw on the companion switch.
    • Identify the same color wire you connected to the blue wire in the first location. Connect this wire to the blue screw on the companion switch.
    • Connect the remaining two wires each to the black and brass screws on the companion switch. (The black and brass screws are interchangeable in this location).
    • አረንጓዴውን ሽቦ ወደ መሬት ያገናኙ.
  7. Wire the second location (Update Existing Switch with Jumper Wire):
    • At the second location, identify the common wire (the one connected to the different colored screw on the old switch). Remove only this tagged wire from the switch.
    • Identify the wire that is the same color as what you attached to the blue wire in the sensor location. Leave this wire connected.
    • Remove the remaining wire from the switch.
    • Connect the two removed wires together, along with the yellow jumper wire (included in package).
    • Connect the other end of the yellow jumper wire to the black screw on the existing switch.
  8. Mount switches and restore power: Secure all switches in their wall boxes, install wall plates, and turn the power back on at the circuit breaker.

Video 2: Installation guide for Lutron Maestro 5 Amp & 6 Amp Switch in multi-location (3-way) setups. This video details how to wire the main sensor and companion switches or update existing switches for multi-point control.

5. ማዋቀር እና ማዋቀር

After installation, your new sensor will take approximately one minute to power up. During this time, you can still manually turn the lights on and off using the paddle switch. Once powered up, it will begin automatic operation.

For detailed instructions on how to change the timeout settings, sensitivity, and sensor mode (occupancy/vacancy), please refer to the full product manual available on the Lutron webጣቢያ፡ lutron.com/OPS5M.

6. ኦፕሬሽን

The Maestro Occupancy Sensing Switch offers both automatic and manual control:

  • ራስ-ሰር አሠራር; The sensor detects motion and ambient light to automatically turn lights on when you enter a room and off when you leave.
  • በእጅ ቁጥጥር You can manually turn the lights on or off at any time by tapping the large paddle switch.

Video 3: Lutron Sensors: Key Benefits. This video highlights the advanced XCT Technology for superior sensitivity, detecting both major and fine motion, ensuring lights stay on when needed.

7. ጥገና

To maintain optimal performance and appearance of your Lutron Maestro switch:

  • በለስላሳ አጽዳ፣ መamp ጨርቅ. ገላጭ ማጽጃዎችን ወይም ፈሳሾችን አይጠቀሙ.
  • Ensure the sensor lens is clear of obstructions for accurate motion detection.

8. መላ መፈለግ

If your Maestro Occupancy Sensing Switch is not functioning as expected, consider the following:

  • Lights not turning on/off automatically: Check the sensor's sensitivity and timeout settings. Ensure there are no obstructions blocking the sensor's view.
  • Lights flickering or not working: Verify all wiring connections are secure and correct. Ensure the power is on at the circuit breaker. Confirm the load (bulbs/fan) is compatible with the switch.
  • የኃይል ጉዳዮች If the switch has no power, check the circuit breaker.

For more detailed troubleshooting, refer to the full product manual or contact Lutron customer support.

9. ዝርዝሮች

Dimensions of the Lutron Maestro Dual Voltage Sensor: 4.7 inches (119 mm) high and 2.9 inches (75 mm) wide

Figure 3: Dimensions of the Lutron Maestro Dual Voltagሠ ዳሳሽ

ባህሪዝርዝር
የሞዴል ቁጥርMS-OPS6M2-DV-GR
የክወና ሁነታአውቶማቲክ
የአሁኑ ደረጃ አሰጣጥ6 Amps
ኦፕሬቲንግ ቁtage120 ቮልት / 277 ቮልት
የወረዳ ዓይነት3-Way/Single Pole
አንቀሳቃሽ ዓይነትየግፊት ቁልፍ
የመቆጣጠሪያ ዘዴንካ
ቀለምግራጫ
ዋትtage720 ዋት
የምርት ልኬቶች2.4 x 4 x 5.8 ኢንች
የእቃው ክብደት0.32 አውንስ
ተስማሚ መሣሪያዎችIncandescent bulbs, Halogen bulbs, Magnetic low-voltage bulbs, Electronic low-voltage bulbs, Non-dim LED bulbs, Non-dim fluorescent bulbs, General purpose fans

10. ዋስትና እና ድጋፍ

For warranty information and customer support, please visit the official Lutron webጣቢያ ወይም በቀጥታ የደንበኛ አገልግሎታቸውን ያግኙ። ለዋስትና ጥያቄዎች የግዢ ደረሰኝዎን ያስቀምጡ።

Lutron Customer Support: www.lutron.com/support

ተዛማጅ ሰነዶች - MS-OPS6M2-DV-GR

ቅድመview Lutron Maestro Occupancy/Vacancy Sensing Switch - Product Specifications and Installation Guide
Detailed specifications, features, installation instructions, and wiring diagrams for the Lutron Maestro Occupancy and Vacancy Sensing Switches, designed for energy-efficient lighting control.
ቅድመview Lutron Maestro Occupancy/Vacancy Sensor Switch: Specifications, Features, and Wiring Diagrams
Comprehensive specifications, features, advanced XCT Technology, custom settings, selection matrix, dimensions, mounting, operation, and detailed wiring diagrams for the Lutron Maestro Occupancy/Vacancy Sensor Switch. Learn about its energy-saving capabilities and installation options.
ቅድመview የሉትሮን ማይስትሮ ዳሳሽ ማብሪያ / ማጥፊያ ከኮምፓኒሽ ማብሪያ / ማጥፊያ ጋር የመጫኛ መመሪያ
ይህ መመሪያ ለነጠላ-ምሰሶ፣ ለ3-መንገድ እና ለ4-መንገድ አፕሊኬሽኖች የሉትሮን ማይስትሮ ዳሳሽ ማብሪያ / ማጥፊያዎችን ከአጃቢ ማብሪያ / ማጥፊያዎች ጋር ለመጫን እና ለማገናኘት ዝርዝር መመሪያዎችን ይሰጣል። የሽቦ ዲያግራሞችን፣ የማብሪያ / ማጥፊያ መለያን እና አስፈላጊ የደህንነት ጥንቃቄዎችን ይሸፍናል።
ቅድመview Lutron Maestro Occupancy Sensing Switch Installation Guide
Detailed installation instructions and specifications for the Lutron Maestro MS-OPS2 and MS-VPS2 occupancy sensing switches. Covers wiring, custom settings, important safety notes, and limited warranty information.
ቅድመview Lutron Occupancy Sensing Switch Installation Guide
A comprehensive guide for installing the Lutron Occupancy Sensing Switch (MS-OPS2, MS-VPS2), covering wiring, setup, and troubleshooting.
ቅድመview Lutron Maestro Dual Technology Sensor Switch Installation Guide
Comprehensive installation guide for the Lutron Maestro Dual Technology Sensor Switch (MS-A102, WMS-A102, MS-A102-V, WMS-A102-V). Covers wiring, setup, custom settings, troubleshooting, and important safety notes for occupancy and vacancy lighting controls.