1. መግቢያ
The Fire-Lite ES-50X is an advanced 50-point addressable fire alarm control panel designed for small to medium-sized applications. It features a built-in communicator, supports up to 50 addressable devices, and includes a real-time clock/calendar with four programmable function keys. This manual provides essential information for the proper installation, operation, and maintenance of the ES-50X panel to ensure reliable fire detection and notification.

ምስል 1፡ ፊት ለፊት view of the Fire-Lite ES-50X Addressable Alarm Control Panel. The panel is housed in a red enclosure with a central control interface featuring an LCD display, keypad, and function buttons. A key lock is visible on the right side of the enclosure.
2. የደህንነት መረጃ
ጠቃሚ፡- Read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, serious injury, or death. This device must be installed by qualified personnel in accordance with all local and national electrical codes and standards, including NFPA 72.
- የኤሌክትሪክ አደጋ; Disconnect all power sources before servicing or installing the panel.
- የባትሪ ደህንነት፡ Use only recommended battery types. Dispose of batteries according to local regulations.
- መሬት ላይ Ensure proper grounding of the panel and all connected devices.
- የአካባቢ ሁኔታዎች; Install the panel in a dry, clean environment within specified temperature and humidity ranges.
- የስርዓት ሙከራ The fire alarm system must be tested regularly as per NFPA 72 and local authority having jurisdiction (AHJ) requirements.
3. ማዋቀር እና መጫን
3.1 የጥቅል ይዘቶች
መጫኑን ከመጀመርዎ በፊት ሁሉም አካላት መኖራቸውን ያረጋግጡ-
- Fire-Lite ES-50X Control Panel
- የመጫኛ መመሪያ
- ሃርድዌር ማፈናጠጥ
- Keys for Enclosure Lock
3.2 ፓነልን መጫን
The ES-50X panel is designed for surface mounting. Choose a secure, dry location that is easily accessible for servicing and visible for status indication.
- Mark the desired mounting holes on the wall using the panel's enclosure as a template.
- Drill appropriate pilot holes for the mounting screws.
- Secure the panel to the wall using the provided mounting hardware. Ensure the panel is level and securely fastened.
3.3 የወልና ግንኙነቶች
All wiring must comply with NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm and Signaling Code), as well as local codes.
- የኤሲ ኃይል ግንኙነት፡- Connect the main AC power supply to the designated terminals. Ensure a dedicated circuit breaker is used.
- የባትሪ ግንኙነት፡- Connect the standby batteries to the battery terminals. Observe correct polarity.
- SLC (Signaling Line Circuit) Wiring: Connect addressable devices (smoke detectors, heat detectors, modules) to the SLC terminals. Follow the wiring diagrams provided in the detailed installation manual for proper loop configuration.
- NAC (Notification Appliance Circuit) Wiring: Connect notification appliances (horns, strobes) to the NAC terminals. Ensure proper supervision and power calculations.
- Auxiliary Outputs/Inputs: Connect any auxiliary devices or monitoring inputs as required by the system design.
3.4 የመጀመሪያ ኃይል-አፕ
After all wiring is complete and verified:
- Ensure all field wiring is correctly terminated and free of shorts or opens.
- Connect the standby batteries.
- Apply AC power to the panel. The panel will perform a self-test and then display its operational status.
- Verify that the panel indicates a "Normal" or "System Healthy" status. Address any trouble conditions immediately.
4. የአሠራር መመሪያዎች
4.1 የቁጥጥር ፓነል በይነገጽ
The ES-50X features an LCD display, a numeric keypad, and dedicated function buttons for system interaction.
- LCD ማሳያ፡- Shows system status, event messages, and menu options.
- የቁልፍ ሰሌዳ Used for entering codes and navigating menus.
- የተግባር ቁልፎች፡-
- ACK (Acknowledge): Silences audible alarms and acknowledges new events.
- ዝምታ፡ Silences notification appliances (horns/strobes) after an alarm.
- ዳግም አስጀምር Resets the system after an alarm or trouble condition, clearing latched events.
- ሙከራ: Initiates system test functions (requires appropriate access level).
4.2 ለማንቂያዎች ምላሽ መስጠት
When an alarm occurs, the panel will activate notification appliances and display alarm information.
- እውቅና ይስጡ የሚለውን ይጫኑ ኤሲኬ button to silence the panel's internal buzzer and acknowledge the alarm. The LCD will show the alarm location.
- ዝምታ፡- After verifying the situation and ensuring safety, press the ዝምታ button to silence horns and strobes. Do not silence if there is an active fire or danger.
- መርምር፡ Proceed to the alarm location to investigate the cause.
- ዳግም ማስጀመር Once the cause of the alarm is resolved and the area is safe, press the ዳግም አስጀምር button. The panel will attempt to clear the alarm condition and return to normal. If the alarm persists, the condition has not been resolved.
4.3 Viewing System Status and Events
The panel's display provides real-time system status. Use the navigation buttons (up/down arrows) to scroll through event history or system menus.
- መደበኛ፡ Indicates the system is operating correctly with no active alarms, troubles, or supervisory conditions.
- ማንቂያ፡- Indicates a fire alarm condition.
- ችግር፡- Indicates a fault in the system (e.g., open circuit, ground fault, low battery).
- ተቆጣጣሪ፡ Indicates a condition that requires attention but is not an immediate fire alarm (e.g., sprinkler valve closed).
5. ጥገና
Regular maintenance is crucial for the reliable operation of your fire alarm system. All maintenance should be performed by qualified personnel.
5.1 መደበኛ ቼኮች (ወርሃዊ)
- Verify the panel displays "Normal" status.
- Check for any visible damage to the panel or connected devices.
- Test a different initiating device (e.g., smoke detector, pull station) each month to ensure proper alarm activation and notification. Reset the system after each test.
5.2 Annual Inspection and Testing
A comprehensive annual inspection and test of the entire fire alarm system should be conducted by a certified fire alarm technician in accordance with NFPA 72.
- Full system test, including all initiating devices, notification appliances, and control functions.
- Battery load test and voltagሠ ቼክ።
- Verification of communication with the central monitoring station (if applicable).
- Cleaning of smoke detectors.
5.3 የባትሪ መተካት
Standby batteries typically have a lifespan of 3-5 years. Replace them proactively or when the panel indicates a low battery trouble condition.
- Disconnect AC Power: Turn off the circuit breaker supplying power to the panel.
- Disconnect Old Batteries: Carefully disconnect the old batteries, observing polarity.
- አዲስ ባትሪዎችን ጫን Connect new, fully charged batteries of the correct type and rating.
- Restore AC Power: Turn on the circuit breaker. The panel should clear the battery trouble.
- አስወግድ፡ በአካባቢው የአካባቢ ጥበቃ ደንቦች መሰረት የድሮ ባትሪዎችን በኃላፊነት ያስወግዱ።
6. መላ መፈለግ
This section provides solutions to common issues. For complex problems, contact a qualified fire alarm technician.
| ችግር | ሊሆን የሚችል ምክንያት | መፍትሄ |
|---|---|---|
| Panel displays "System Trouble" | Various issues: low battery, AC power loss, ground fault, open circuit on SLC/NAC. | Check AC power. Verify battery connections and voltage. Consult the panel display for specific trouble codes and refer to the detailed installation manual for diagnostics. |
| Notification appliances do not activate during alarm | NAC wiring fault, power supply issue, silenced by mistake. | Check NAC wiring for opens or shorts. Verify NAC power supply. Ensure the system is not in "Silence" mode. |
| Panel does not reset after alarm | Alarm condition still present, device not cleared. | Ensure the initiating device (e.g., smoke detector) has cleared the alarm condition. Check for residual smoke or heat. If a pull station was activated, ensure it is reset. |
| Device fault on SLC loop | Damaged device, incorrect wiring, address conflict. | Identify the specific device from the panel display. Check wiring to the device. Verify device address. Replace faulty device if necessary. |
7. ዝርዝሮች
Key technical specifications for the Fire-Lite ES-50X Addressable Alarm Control Panel:
- የሞዴል ቁጥር፡- ES-50X
- የምርት ስም፡ እሳት-ላይት
- የመሳሪያ አቅም፡- Up to 50 addressable devices
- የኃይል ምንጭ፡- AC (main), Battery (standby)
- የማንቂያ አይነት፡ የሚሰማ
- ቀለም፡ ማሩን
- የእቃው ክብደት፡ 23.5 ፓውንድ (10.68 ኪሎግራም)
- የጥቅል መጠኖች: 22.2 x 20 x 6.2 ኢንች
- አምራች፡ እሳት-ላይት
- ዩፒሲ፡ 783008112622
- ቅጥ፡ ባህላዊ
8. ዋስትና እና ድጋፍ
For specific warranty details, please refer to the warranty statement included with your product packaging or contact Fire-Lite directly. Fire-Lite products typically come with a limited warranty covering defects in materials and workmanship.
የቴክኒክ ድጋፍ
For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact your authorized Fire-Lite distributor or a certified fire alarm technician. Do not attempt to repair the panel yourself, as this may void the warranty and compromise system integrity.
For general information about Fire-Lite products, visit the official Fire-Lite webጣቢያ.