ABB XT1C 160

ABB TMAX XT1C 160 Circuit Breaker User Manual

Model: XT1C 160 | Brand: ABB

መግቢያ

This manual provides essential information for the safe and effective installation, operation, and maintenance of the ABB TMAX XT1C 160 Molded Case Circuit Breaker (MCCB). Please read this manual thoroughly before attempting any installation or operation.

የደህንነት መረጃ

WARNING: Electrical shock hazard. Only qualified personnel should install, operate, or maintain this device.

ምርት አልቋልview

The ABB TMAX XT1C 160 is a 3-pole fixed molded case circuit breaker with a thermomagnetic release, designed for protection against overloads and short circuits in electrical systems. It features front terminals for easy connection.

ABB TMAX XT1C 160 Molded Case Circuit Breaker with specifications visible

This image shows the ABB TMAX XT1C 160 circuit breaker. Key features visible include the ABB logo, the SACE Tmax branding, the 'off' position indicator, and the current rating adjustment dials (MED 106A, MAX 125A). The top section displays technical specifications such as rated operational voltage (Ue), rated ultimate short-circuit breaking capacity (Icu), and rated impulse withstand voltage (Uimp). The breaker is a 3-pole design with front terminals.

ቴክኒካዊ ዝርዝሮች

መለኪያዋጋ
ሞዴልXT1C 160
የአሁኑ ደረጃ አሰጣጥ125 Amps
የዋልታዎች ብዛት3
የወረዳ ሰባሪ ዓይነትመደበኛ, የሙቀት-መግነጢሳዊ
የመጫኛ አይነትDIN የባቡር ተራራ
ደረጃ የተሰጠው ኦፕሬሽናል ጥራዝtagሠ (ዩኤ)690V AC፣ 500V ዲሲ
ደረጃ የተሰጠው እጅግ በጣም ጥሩ የአጭር-ወረዳ መሰባበር አቅም (Icu)25kA @ 415VAC
ደረጃ የተሰጠው ግፊት መቋቋም ጥራዝtagሠ (Uimp)8 ኪ.ቮ
የመልቀቂያ ዓይነትThermomagnetic (TMD)
ተርሚናሎችፊት ለፊት
ደረጃዎችIEC60947-2, NEMA AB1
አምራችኤ.ቢ.ቢ.
ASINB07JJL7XGD

መጫን

ከመጫኑ በፊት; Ensure the power supply is disconnected and locked out according to safety procedures. Verify the circuit breaker's ratings match the application requirements.

በመጫን ላይ

The XT1C 160 is designed for DIN rail mounting.

  1. Securely attach the DIN rail to the mounting surface in the electrical enclosure.
  2. Align the circuit breaker's rear clips with the DIN rail.
  3. Press firmly until the breaker clicks into place, ensuring it is securely fastened.

የወልና

Connect the power supply and load cables to the designated front terminals.

ኦፕሬሽን

ማብራት/ማጥፋት

The circuit breaker has a toggle handle for manual operation.

Current Adjustment (TMD Release)

The thermomagnetic release allows for adjustment of the rated current (In) and instantaneous trip setting.

ጥገና

Regular maintenance ensures the longevity and reliable operation of the circuit breaker. Always disconnect power before performing any maintenance.

መላ መፈለግ

ችግርሊሆን የሚችል ምክንያትመፍትሄ
ሰባሪ በተደጋጋሚ ይጓዛልOverload or short circuit in the protected circuit.Identify and remove the overload. Check for short circuits in the connected circuit using appropriate testing equipment.
Breaker does not reset after trippingPersistent fault in the circuit or internal damage to the breaker.Ensure the fault is completely cleared. If it still doesn't reset, the breaker may be damaged internally and require replacement by a qualified technician.
በተርሚናሎች ላይ ከመጠን በላይ ማሞቅLoose connections or undersized wiring for the load.Disconnect power and tighten terminal screws to the specified torque. Verify wire gauge is appropriate for the maximum current.
Breaker does not trip on faultBreaker malfunction or incorrect rating for the application.Immediately disconnect power. Do not use the breaker. It must be inspected and potentially replaced by a qualified professional. Verify the breaker's ratings match the system requirements.

ዋስትና እና ድጋፍ

For detailed warranty information and technical support, please refer to the official ABB website or contact your authorized ABB distributor. Keep your purchase receipt for warranty claims.

አምራች፡ ኤቢቢ

ASIN: B07JJL7XGD

ለመጀመሪያ ጊዜ የሚገኝበት ቀን፡ ጁላይ 3፣ 2019

ለተጨማሪ እርዳታ፣ ይጎብኙ ABB Store on Amazon.

ተዛማጅ ሰነዶች - XT1C 160

ቅድመview ABB SACE Tmax for Special Applications: Circuit Breakers & Switch-Disconnectors
Explore ABB's SACE Tmax range of molded case circuit-breakers and switch-disconnectors for special applications. Offering high breaking capacity, flexibility, and advanced protection compliant with UL and IEC standards for DC and AC systems up to 1500V DC and 1150V AC.
ቅድመview የABB Tmax T5 የወረዳ መከፋፈያ ጭነት እና ቴክኒካዊ መረጃ
እንደ PR221DS ያሉ የተለያዩ ተከታታይ ክፍሎችን ጨምሮ ለ ABB Tmax T5 የወረዳ ማብሪያ ወንበሮች አጠቃላይ ቴክኒካዊ ዝርዝሮች፣ የልኬት ስዕሎች እና የመጫኛ መመሪያዎች።
ቅድመview ABB SACE Tmax XT ካታሎግ፡ ዝቅተኛ ቮልትtagኢ የተቀረጸ የጉዳይ ሰርክዩት-ብሬከርስ
ዘመናዊ የዝቅተኛ ቮልት ክልል የሆነውን የABB SACE Tmax XT ተከታታይ ክፍልን ያስሱtagለተለያዩ የኢንዱስትሪ እና የንግድ አፕሊኬሽኖች የላቀ አፈፃፀም፣ ግንኙነት፣ የአጠቃቀም ቀላልነት እና ጠንካራ ጥበቃ የሚሰጡ የኢ-ሞልድ ኬዝ ሰርኪዩት ብሬከርስ።
ቅድመview የSACE Tmax XT የወረዳ መከፋፈያ የመጫኛ መመሪያ
ለኤቢቢ ኤስኤሲ ቲማክስ ኤክስቲ የወረዳ ማብሪያና ማጥፊያዎች አጠቃላይ የመጫኛ መመሪያዎች እና የሚመከሩ ሁኔታዎች፣ የኤሲ እና የዲሲ አፕሊኬሽኖችን፣ የሽቦ ዲያግራሞችን፣ የልኬት መረጃዎችን እና የጉዞ ሙከራ ሂደቶችን የሚሸፍኑ።
ቅድመview ABB SACE® Tmax® XT የተቀረጸ የኬዝ ሰርኪት ብሬከርስ፡ የአከፋፋይ ፍልሰት መመሪያ ከ Spectra™
ይህ የኤቢቢ የአከፋፋይ ፍልሰት መመሪያ አጠቃላይ አጠቃላይ እይታን ያቀርባልview የSACE® Tmax® XT ቅርጽ ያላቸው የኬዝ ሰርኩዊት መቆራረጫዎችን በመጠቀም ባህሪያቸውን፣ አፕሊኬሽኖቻቸውን እና ጥቅሞቻቸውን በዝርዝር ያቀርባል። ተጠቃሚዎችን ከስፔክትራ™ ተከታታይ ስለማዛወር ይመራል፣ የስቶኪንግ ስልቶችን ያቀርባል፣ መለዋወጫዎችን ይዘረዝራል እና የምርት ቅደም ተከተል አወቃቀሮችን ያብራራል። ለኤሌክትሪክ አከፋፋዮች እና ለዝርዝሮች አስፈላጊ ነው።
ቅድመview ABB SACE Tmax T Generation: ዝቅተኛ መጠንtagኢ የተቀረጸ-ኬዝ ሰርኪዩት-ብሬከርስ (250A-1600A) የቴክኒክ ካታሎግ
የABB SACE Tmax T Generation ክልል ዝቅተኛ ቮልት ያስሱtage moulded-case circuit-breakers, designed for robust electrical protection and reliable power distribution from 250 A to 1600 A. This technical catalogue details features, specifications, and applications.