Daytech E-01W

የዴይቴክ ገመድ አልባ ተንከባካቢ ፔጀር ሲስተም የተጠቃሚ መመሪያ

Model: E-01W | Brand: Daytech

1. ምርት አብቅቷልview

The Daytech Wireless Caregiver Pager System is designed to provide peace of mind and independence for individuals needing assistance, as well as for their caregivers. This wireless alert system allows patients or elderly persons to quickly call for help with a simple press of a button, ensuring timely assistance in private households, hospitals, nursing homes, and other care environments. The system offers a reliable connection with a working range of up to 320 feet (120 meters).

Daytech Wireless Caregiver Pager System with 3 Receivers, 2 Watch Pagers, and 2 Call Buttons

Figure 1: Complete Daytech Wireless Caregiver Pager System components.

2. ምን ይካተታል

Your Daytech Wireless Caregiver Pager System package includes the following components:

  • 3 x ተሰኪ ተቀባዮች
  • 2 x SOS Watch Pagers
  • 2 x SOS Call Buttons (with lanyards)
  • Required 12V batteries (pre-installed or included for call buttons)
  • የተጠቃሚ መመሪያ (ይህ ሰነድ)
Various components of the Daytech Caregiver Pager System, including receivers, watch pagers, and call buttons, demonstrating different usage methods like wall mounting, wearing around the neck, and on the wrist.

ምስል 2 - ተጠናቀቀview of system components and common usage scenarios.

3. መጀመር (ማዋቀር)

3.1 ተቀባይ ማዋቀር

  1. መቀበያውን ይሰኩ፦ Plug the receiver into a standard wall socket. The receiver will emit a sound and its LED light will flash, indicating it is powered on.

  2. የስልክ ጥሪ ድምፅ ምረጥ፡- Press the Forward Button or Backward Button on the side of the receiver to cycle through the 20 available ringtones. Choose your preferred alert sound.

  3. የድምጽ መጠን አስተካክል; Press the Volume Control button on the side of the receiver to adjust the volume level. There are 5 levels, ranging from 0dB (silent) to 110dB (loudest).

ዝርዝር view of the receiver showing volume control, backward button, forward button, and LED light melody display, along with dimensions.

Figure 3: Receiver controls and dimensions.

3.2 Pairing Transmitters (Call Buttons & Watch Pagers)

To ensure your call buttons and watch pagers communicate with the receiver, they must be paired:

  1. የማጣመሪያ ሁነታን ያስገቡ ፦ Press and hold the Volume Control button on the receiver until the LED light flashes and the receiver emits a "ding-dong" sound. This indicates the receiver is in pairing mode.

  2. አስተላላፊን አግብር፡ Within 5 seconds of the receiver entering pairing mode, press the SOS button on the watch pager or the CALL button on the call button unit. The receiver will emit a "ding-dong" sound and its LED light will flash, confirming successful pairing.

  3. ማጣመርን ያረጋግጡ፡ Press the button on the transmitter again. The receiver should respond with the selected ringtone and flash, confirming the pairing is active.

  4. Pair Additional Transmitters: Repeat steps 1-3 for each additional call button or watch pager you wish to pair with the receiver.

Four-step visual guide on how to modify ringtone and pair the Daytech Caregiver Pager System, showing plugging in the receiver, selecting ringtone, entering pairing mode, and pressing the call button to pair.

Figure 4: Visual guide for pairing transmitters.

Video: Learn how to pair multiple call buttons with your Daytech Caregiver Pager System for expanded coverage.

3.3 Call Button Installation

The call buttons offer flexible installation options:

  • Lanyard አባሪ፡ Attach the included lanyard to the call button for easy wearing around the neck, ensuring it's always accessible.

  • የግድግዳ ተራራ Use the provided 3M double-sided adhesive patches to affix the call button to a wall or other flat surface. This is ideal for fixed locations like bathrooms or beside a bed.

Two solutions for call button installation: attaching a lanyard or using a 3M double-sided patch for wall mounting.

Figure 5: Call button installation methods.

4. ኦፕሬሽን

4.1 Using the Pager System

Once set up, operating the Daytech Caregiver Pager System is straightforward:

  • Initiate Alert: When assistance is needed, simply press the large SOS button on the watch pager or the CALL button on the call button unit. This sends a wireless signal to the paired receiver(s).

  • Receive Alert: The receiver(s) will sound the selected ringtone and flash their LED light, immediately notifying the caregiver of the need for assistance.

Video: See how easy it is to get assistance with just a push of a button.

4.2 ውጤታማ ክልል

The system boasts a working distance of up to 320 feet (120 meters) in an open area. This allows caregivers to move freely around the house or facility while remaining within range to receive alerts.

Diagram illustrating the wireless range of the Daytech Caregiver Pager System within a house, showing the watch pager and receiver communicating over a distance of approximately 100 feet (30 meters).

Figure 6: Wireless working distance illustration.

4.3 የመተግበሪያ ሁኔታዎች

This versatile system is suitable for various care needs:

  • የአረጋውያን እንክብካቤ
  • Patient/Disabled Care
  • የልጆች እንክብካቤ
  • Pregnancy Care

ቪዲዮ: አልቋልview of the Daytech Caregiver Pager Call Button system and its applications.

5. ጥገና

5.1 የባትሪ መተካት

The call buttons and watch pagers are battery-powered. When the battery is low, the performance may degrade. Replace batteries as needed.

  • Call Button Battery: The call button uses a 12V battery. To replace, carefully open the back cover using a small screwdriver, remove the old battery, insert the new one with correct polarity, and secure the cover.

  • Watch Pager Battery: The watch pager uses a CR2032 battery. To replace, carefully open the watch casinሰ፣ የድሮውን ባትሪ አስወግድ፣ አዲሱን በትክክለኛ ፖላሪቲ አስገባ እና ሐ መዝጋትasinሰ በአስተማማኝ ሁኔታ.

Video: Instructions on how to attach the lanyard and replace the battery in the call button.

Video: A guide on how to open the watch pager for battery replacement.

5.2 እንክብካቤ እና ጽዳት

The call button unit is splash-proof (IP55 rated) and can withstand splashes of water, making it suitable for use in bathrooms or near sinks. However, it is NOT designed to be immersed in water. The watch pager and alert button unit cannot be immersed in water and should be removed before bathing or showering.

Image showing a call button with water droplets, indicating its IP55 splash-proof rating, along with working temperature range.

Figure 7: Call button IP55 waterproof rating and temperature range.

To clean the units, wipe them with a soft, damp ጨርቅ. ኃይለኛ ኬሚካሎችን ወይም ሻካራ ማጽጃዎችን አይጠቀሙ.

6. መላ መፈለግ

If you encounter any issues with your Daytech Wireless Caregiver Pager System, please refer to the table below for common problems and their solutions:

ችግርሊሆን የሚችል ምክንያትመፍትሄ
Receiver does not sound/flash when button is pressed.Not paired, out of range, low battery in transmitter.Re-pair the transmitter with the receiver. Move closer to the receiver. Replace transmitter battery.
Short working range.Obstructions (thick walls, metal objects), electromagnetic interference, low battery.Relocate receiver to a more central position. Avoid placing near large metal objects. Replace transmitter battery.
Receiver constantly beeps or flashes.Stuck button on transmitter, interference.Check transmitter button for obstruction. Unplug and re-plug receiver.
የስልክ ጥሪ ድምፅ ወይም የድምጽ መጠን መቀየር አይቻልም።ትክክል ያልሆነ አዝራር ተጫን.Ensure you are pressing the correct Forward/Backward or Volume buttons as described in Section 3.1.

7. ቴክኒካዊ ዝርዝሮች

ባህሪዝርዝር መግለጫ
የሞዴል ቁጥርኢ-01 ዋ
የመቆጣጠሪያ ዘዴንካ
ከፍተኛው ክልል320 ጫማ (120 ሜትር)
የስልክ ጥሪ ድምፅ20 ሊመረጡ የሚችሉ ቃጭሎች
የድምጽ ደረጃዎች5 ደረጃዎች (0-110 dB)
Call Button Waterproof RatingIP55 (የማስረጃ)
የጥሪ አዝራር ባትሪ1 x 12V Alkaline battery (included)
Watch Pager BatteryCR2032 (ተካቷል)
የኃይል ምንጭ (ተቀባይ)AC Plug-in (260 Volts)
የእቃው ክብደት1.15 ፓውንድ (ጠቅላላ ጥቅል)
የጥቅል ልኬቶች5.83 x 5.2 x 4.06 ኢንች

8. ዋስትና እና ድጋፍ

Daytech is committed to providing reliable products and excellent customer service. Your Daytech Wireless Caregiver Pager System comes with a full year’s warranty and a money-back guarantee.

For any questions, troubleshooting assistance, or support needs, please contact our round-the-clock customer service team. We are here to ensure your peace of mind when caring for your loved ones.

ተዛማጅ ሰነዶች - ኢ-01 ዋ

ቅድመview DAYTECH Wireless Vibrable Caregiver Pager System User Manual
Comprehensive user manual for the DAYTECH Wireless Vibrable Caregiver Pager System. Learn how to set up, pair transmitters and receivers, adjust settings, and troubleshoot common issues for this emergency alert system.
ቅድመview ሁለገብ ፔጀር ኦፕሬሽን መመሪያ እና የተጠቃሚ መመሪያ
ሁለገብ የተጠቃሚ ማንዋል ለ Multifunctional Pager፣ መልኩን በዝርዝር የሚገልጽ፣ የማብራት ሂደቶች፣ ከኤስኦኤስ ቁልፍ ጋር በማጣመር፣ የሞባይል መተግበሪያ ግንኙነት (Tuya Smart/Smart Life)፣ የመተግበሪያ ክንዋኔዎች የማንቂያ ቅንብሮችን እና የመሣሪያ አስተዳደርን፣ የመጫኛ መመሪያን፣ ዝርዝር መግለጫዎችን፣ የመላ ፍለጋ ጥያቄ እና መልስ እና ከሽያጭ በኋላ አገልግሎት መረጃ።
ቅድመview ገመድ አልባ ስማርት አንጓ ፔጀር የተጠቃሚ መመሪያ እና መመሪያ
ይህ የተጠቃሚ መመሪያ ለገመድ አልባ ስማርት አንጓ ተቀባይ/ፔጀር ዝርዝር መመሪያዎችን እና ዝርዝር መግለጫዎችን ያቀርባል፣ የSW06 ሞዴልን ማዋቀር፣ አሠራር፣ መላ መፈለግ እና ቴክኒካዊ ዝርዝሮችን ይሸፍናል።
ቅድመview የዴይቴክ ገመድ አልባ ቃጭል/ፔጀር የተጠቃሚ መመሪያ - INST-EN-CC01-T-20230214
ለዴይቴክ ዋየርለስ ቺም/ፔጀር (INST-EN-CC01-T-20230214) የተሟላ የተጠቃሚ መመሪያ፣ ባህሪያትን፣ ዝርዝር መግለጫዎችን፣ መጫንን፣ አሠራርን፣ መላ መፈለግን እና ጥገናን የሚሸፍን።
ቅድመview የዴይቴክ ኢ-05W የእጅ አንጓ ጥሪ አዝራር የተጠቃሚ መመሪያ እና ተገዢነት
የዴይቴክ ኢ-05W የእጅ አንጓ ጥሪ አዝራር (ሞዴል፡ E-05W-GY) የተጠቃሚ መመሪያ፣ ምርቱን በ...viewየባትሪ መተካት፣ የአሠራር ሂደት እና የFCC/ISED ተገዢነት መረጃ።
ቅድመview የዴይቴክ LC01 ገመድ አልባ ፔጀር/ቺም ሲስተም የተጠቃሚ መመሪያ
ለዴይቴክ LC01 ገመድ አልባ ፔጀር እና ቺም ሲስተም አጠቃላይ የተጠቃሚ መመሪያ፣ ባህሪያትን፣ የምርት ዲያግራሞችን፣ የመጫኛ መመሪያዎችን፣ የአሠራር መመሪያዎችን፣ መላ ፍለጋን፣ ዝርዝር መግለጫዎችን እና የስልክ ጥሪ ድምፅ ዝርዝርን ያካትታል።