Roca A5A2J18C00

Roca VICTORIA PLUS A5A2J18C00 Thermostatic Bath-Shower Column

መመሪያ መመሪያ

1. መግቢያ

This manual provides detailed instructions for the installation, operation, and maintenance of your Roca VICTORIA PLUS A5A2J18C00 Thermostatic Bath-Shower Column. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

Roca VICTORIA PLUS A5A2J18C00 Thermostatic Bath-Shower Column

Figure 1: Roca VICTORIA PLUS A5A2J18C00 Thermostatic Bath-Shower Column

2. የደህንነት መረጃ

  • የውሃ አቅርቦት መስመሮቹን ከመጫንዎ በፊት ሁሉም የውሃ አቅርቦት መስመሮች መዘጋታቸውን ያረጋግጡ።
  • ስለ ማንኛውም የመጫን ሂደቱ ክፍል እርግጠኛ ካልሆኑ ብቃት ያለው ቧንቧ ያማክሩ።
  • Do not use abrasive cleaners or harsh chemicals on the product, as this may damage the finish.
  • Regularly check for leaks and address them promptly to prevent water damage.
  • The thermostatic mixer is designed to maintain a constant water temperature. Do not tamper with the factory settings unless necessary and with caution.

3. የጥቅል ይዘቶች

ከመጫንዎ በፊት ሁሉም ክፍሎች መኖራቸውን እና ምንም ጉዳት እንደሌላቸው ያረጋግጡ፡

  • ቴርሞስታቲክ ቀላቃይ
  • Adjustable height shower column (1295 mm to 1670 mm)
  • Overhead shower head (ø 245 mm)
  • Hand shower (ø 100 mm, 3 functions)
  • 1.7 m metallic flexible hose
  • Shower column mounting kit

4. ዝርዝሮች

ባህሪዝርዝር መግለጫ
የሞዴል ቁጥርA5A2J18C00
የምርት ስምሮካ
ቁሳቁስብረት
ቀለም / ጨርስChrome
የመጫኛ አይነትየግድግዳ ተራራ
የሚስተካከለው ቁመትከ 1295 ሚሜ እስከ 1670 ሚሜ
Overhead Shower Diameterø 245 ሚሜ
Hand Shower Diameterø 100 mm (3 functions)
የሆስ ርዝመት1.7 ሜ
የእቃዎች ቁጥር።1
የምርት ልኬቶች128.5 x 53.5 x 137 ሴ.ሜ
የምርት ክብደት6.16 ኪ.ግ
Technical drawing with dimensions of the Roca VICTORIA PLUS shower column

Figure 2: Technical drawing with key dimensions for installation.

5. መጫን

Professional installation is recommended. Ensure you have all necessary tools and safety equipment before proceeding.

5.1. የመጫኛ ቦታን ያዘጋጁ

  1. ወደ መታጠቢያ ቤትዎ ዋናውን የውሃ አቅርቦት ያጥፉ.
  2. Remove any existing shower fixtures.
  3. Clean the wall surface where the shower column will be mounted.

5.2. Mount the Thermostatic Mixer

  1. Install the eccentric connectors into the wall water outlets. Ensure they are securely tightened and properly aligned.
  2. Attach the decorative escutcheons over the eccentric connectors.
  3. Connect the thermostatic mixer to the eccentric connectors. Ensure the hot water inlet (marked red) and cold water inlet (marked blue) are correctly aligned. Tighten the nuts using a wrench, protecting the finish with a cloth.

5.3. Install the Shower Column

  1. Attach the lower part of the shower column to the top outlet of the thermostatic mixer.
  2. Assemble the adjustable height mechanism onto the main column.
  3. Mark the position for the upper wall bracket on the wall, ensuring the column is vertical and at the desired height.
  4. Drill holes at the marked positions, insert wall plugs, and secure the upper wall bracket.
  5. Secure the shower column to the upper wall bracket using the provided screws and Allen key.

5.4. Attach Shower Components

  1. Screw the overhead shower head onto the shower arm. Ensure a watertight seal.
  2. Connect the metallic flexible hose to the hand shower and the outlet on the thermostatic mixer.
  3. Place the hand shower into its adjustable holder on the column.

6. ኦፕሬሽን

6.1. Thermostatic Mixer

  • የሙቀት መቆጣጠሪያ; The right handle controls the water temperature. Push the safety button and turn to adjust above 38°C.
  • ፍሰት መቆጣጠሪያ፡- The left handle controls the water flow and diverts water between the overhead shower, hand shower, and bath filler (if applicable).

6.2. Hand Shower Functions

The hand shower features 3 spray functions. Rotate the shower head face to switch between spray patterns.

6.3. Adjustable Height and Angle

  • The hand shower holder can be adjusted up or down the column and tilted to your preferred angle.
  • The overhead shower head can be tilted and swiveled to adjust the spray direction.

7. ጥገና

7.1. ማጽዳት

  • Clean the chrome surfaces regularly with a soft cloth and mild soap or a non-abrasive cleaner specifically designed for bathroom fixtures.
  • Avoid using abrasive sponges, scouring pads, or harsh chemical cleaners, as these can damage the finish.
  • For shower heads, periodically rub the silicone nozzles to dislodge any limescale buildup.

7.2. Limescale Removal

In hard water areas, limescale can build up. Use a descaling solution suitable for bathroom fixtures, following the manufacturer's instructions. Rinse thoroughly after cleaning.

8. መላ መፈለግ

ችግርሊሆን የሚችል ምክንያትመፍትሄ
የውሃ ፍሰት ወይም ዝቅተኛ ግፊት የለምWater supply off, clogged filters, kinked hoseCheck water supply, clean filters in the mixer, straighten hose.
የውሃ ሙቀት ይለዋወጣልInconsistent hot/cold water supply, thermostatic cartridge issueCheck water heater, consult a professional for cartridge inspection.
ከግንኙነት ፍንጣቂዎችLoose connections, damaged sealsTighten connections, replace seals/washers if damaged.
Shower head/hand shower spray unevenLimescale buildup in nozzlesClean nozzles by rubbing or using a descaling solution.

9. ዋስትና እና ድጋፍ

For warranty information and customer support, please refer to the documentation provided with your purchase or visit the official Roca webጣቢያ. ለዋስትና ጥያቄዎች የግዢ ማረጋገጫዎን ያስቀምጡ።