1. መግቢያ
This manual provides detailed instructions for the installation, operation, and maintenance of the SINOTIMER DDS6619 Din Rail Single Phase Energy Meter. This device is designed for measuring active energy consumption in single-phase AC systems. Please read this manual thoroughly before installation and use to ensure proper function and safety.

ምስል 1፡ ፊት view of the SINOTIMER DDS6619 Din Rail Single Phase Energy Meter, showing the LCD display and terminal connections.
2. የደህንነት መረጃ
በመሳሪያው ላይ ጉዳት እና ጉዳት እንዳይደርስ ለመከላከል የሚከተሉትን የደህንነት ጥንቃቄዎች ይከተሉ፡
- መጫኑ መከናወን ያለበት ብቃት ባላቸው ሰዎች ብቻ ነው።
- ከመጫንዎ ወይም ከጥገናዎ በፊት ዋናው የኃይል አቅርቦት መቋረጡን ያረጋግጡ።
- Do not operate the meter in environments with excessive moisture, dust, or corrosive gases.
- Verify correct wiring connections according to the provided diagram to avoid damage or malfunction.
- The meter is designed for indoor use only.
- Do not attempt to open or repair the meter yourself. Contact qualified service personnel.
3. የጥቅል ይዘቶች
ጥቅሉን ከከፈቱ በኋላ ሁሉም እቃዎች መኖራቸውን እና ያልተበላሹ መሆናቸውን ያረጋግጡ፡-
- 1 x SINOTIMER DDS6619 Din Rail Single Phase Energy Meter
- 1 x የተጠቃሚ መመሪያ (ይህ ሰነድ)
4. የምርት ባህሪዎች
The DDS6619 energy meter offers a range of features for efficient power monitoring:
- Innovative Dual-Row Display: The top row rotates to show temporary kWh, voltage, current, power, power factor, and frequency. The second row displays total power consumption.
- LCD የጀርባ ብርሃን፡ Blue LCD HD backlight ensures clear visibility in various lighting conditions.
- ከፍተኛ ትክክለኛነት; Class 1.0 meter, utilizing microelectronics and digital processing for reliable energy measurement.
- 6-in-1 Multimeter Functionality: Displays Total Energy (kWh), Temporary Energy (kWh), Voltage (V), Current (A), Power (W), Frequency (Hz), and Power Factor (PF).
- Energy Memory: All electric energy data is automatically stored and memorized upon power loss.
- ተግባርን ዳግም ማስጀመር፡ Temporary kWh data can be reset to zero for specific measurement needs. Total power consumption remains unaffected.
- የጠፈር ብቃት ያለው ንድፍ፡ Standard 36mm width, compatible with universal DIN 35mm guide rails.
- ዘላቂ ግንባታ; Made from flame-retardant, high-quality ABS material for impact resistance and long service life.

Image 2: Illustration of the DDS6619 display modes, demonstrating how temporary and total readings for various electrical parameters are shown.
5. ማዋቀር እና መጫን
5.1 ልኬቶች
The meter is designed for standard DIN rail mounting. Refer to the dimensions below for proper planning:

Image 3: Dimensional drawing of the DDS6619 meter, indicating its width (36.3mm), height (78.5mm), and depth (65.8mm) for installation planning.
5.2 መጫን
- Ensure the main power supply is turned off at the circuit breaker before proceeding.
- Mount the DDS6619 meter onto a standard 35mm DIN rail in your electrical panel.
- Ensure the meter is securely fastened to prevent movement.
5.3 የሽቦ ዲያግራም
Follow the wiring diagram carefully. Incorrect wiring can cause damage to the meter or electrical system.

Image 4: Wiring diagram for the DDS6619 meter, illustrating the correct connections for live (L) and neutral (N) input and output terminals.
- Connect the incoming Live (L) wire to the terminal marked 'L' on the input side.
- Connect the incoming Neutral (N) wire to the terminal marked 'N' on the input side.
- Connect the outgoing Live (L) wire to the terminal marked 'L' on the output side.
- Connect the outgoing Neutral (N) wire to the terminal marked 'N' on the output side.
- Double-check all connections for tightness and correctness before restoring power.
6. የአሠራር መመሪያዎች
6.1 በርቷል
After successful installation and wiring, restore power to the circuit. The meter's LCD display will illuminate, showing the current readings.
6.2 የማሳያ ሁነታዎች
The meter features a dual-row display. The top row cycles through various temporary electrical parameters, while the bottom row consistently shows the total power consumption (kWh).
- Top Row (Rotating Display): Shows temporary kWh, Voltage (V), Current (A), Power (W), Power Factor (PF), and Frequency (Hz). This display automatically cycles through these parameters.
- Bottom Row (Static Display): Always shows the total accumulated power consumption in kWh. This value cannot be reset.
6.3 Reset Function for Temporary kWh
The temporary kWh reading can be reset to zero for monitoring consumption over specific periods.

Image 5: Diagram illustrating the reset function. The top display shows temporary power consumption (resettable), the bottom shows total power consumption (not resettable), and indicates to hold the reset button for 6 seconds.
- Locate the reset button on the front panel of the meter.
- Press and hold the reset button for approximately 6 seconds.
- The temporary kWh value on the top display will reset to zero. The total power consumption on the bottom display will remain unchanged.
7. ዝርዝሮች
| መለኪያ | ዋጋ |
|---|---|
| ሞዴል | ዲ.ዲ.ኤስ6619 |
| ደረጃ የተሰጠው ጥራዝtage | 120 ቪኤሲ |
| ደረጃ የተሰጠው የአሁኑ | 5(80) አ |
| ድግግሞሽ | 60Hz |
| ትክክለኛነት ክፍል | 1.0 |
| ማሳያ | LCD ከሰማያዊ የጀርባ ብርሃን ጋር |
| በመጫን ላይ | 35 ሚሜ የዲን ባቡር |
| ቁሳቁስ | ነበልባል ዘገምተኛ ኤ.ዲ.ኤስ. |
| የጥቅል ልኬቶች | 2.72 x 1.65 x 0.63 ኢንች |
| ክብደት | 0.48 አውንስ |
8. ጥገና
The DDS6619 energy meter requires minimal maintenance. Follow these guidelines to ensure its longevity:
- Keep the meter clean by wiping it with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- የስራ አካባቢው በተጠቀሰው የሙቀት መጠን እና እርጥበት ክልሎች ውስጥ መቆየቱን ያረጋግጡ።
- Periodically check wiring connections for tightness, especially in environments subject to vibration.
- Do not expose the meter to direct sunlight for extended periods, as this may affect the LCD display.
9. መላ መፈለግ
If you encounter issues with your DDS6619 meter, refer to the following common problems and solutions:
| ችግር | ሊሆን የሚችል ምክንያት | መፍትሄ |
|---|---|---|
| ማሳያ/ቆጣሪ አልበራም | No power supply; Incorrect wiring; Faulty meter | Check power supply to the circuit. Verify wiring connections according to the diagram. If problem persists, contact support. |
| ትክክለኛ ያልሆኑ ንባቦች | Incorrect wiring; Overload; External interference | Re-check wiring. Ensure load does not exceed meter's maximum current rating. Isolate from strong electromagnetic fields. |
| Temporary kWh not resetting | Reset button not held long enough | Press and hold the reset button for a full 6 seconds. |
| Total kWh reading is zero or incorrect | Incorrect wiring; Meter malfunction | Verify wiring. Note that total kWh cannot be reset. If consistently incorrect, contact support. |
10. ዋስትና እና ድጋፍ
SINOTIMER products are manufactured to high-quality standards. For warranty information or technical support, please refer to the documentation provided with your purchase or visit the official SINOTIMER webጣቢያ.
በ ላይ ተጨማሪ መረጃ እና የእውቂያ ዝርዝሮችን ማግኘት ይችላሉ SINOTIMER Store on Amazon.