METER-አርማMETER BARO ሞዱል

METER-BARO-Module -product

ባሮ ኢንቴግሬተር መመሪያ

ዳሳሽ መግለጫ

የ BARO ሞዱል የTEROS 31 እና TEROS 32 tensiometers ማትሪክ እምቅ መለኪያዎችን ለማካካስ ትክክለኛ ባሮሜትር ነው። የ BARO ሞዱል በመለኪያ ቦታ ላይ አንድ ወይም ከዚያ በላይ ቴንስዮሜትሮችን ለማካካስ እንደ ገለልተኛ ዳሳሽ ወይም እንደ ዲጂታል/አናሎግ መቀየሪያ የተገናኘ TEROS 31 ወይም TEROS 32 ዋጋን ለማካካስ እና የ SDI-12 ምልክትን ወደ አናሎግ ቮልት ለመቀየር ሊያገለግል ይችላል።tagሠ ውፅዓት (ባለ 8-ሚስማር ስሪት ብቻ)። የ BARO ሞዱል እና TEROS 32 ጥምር እንደ T8 tensiometer ምትክ ጥቅም ላይ ሊውል ይችላል. ይህ ዳሳሽ መለኪያዎችን እንዴት እንደሚሰራ የበለጠ ዝርዝር መግለጫ ለማግኘት የ BARO ሞዱል የተጠቃሚ መመሪያን ይመልከቱ።

METER-BARO-Module- (1)

አፕሊኬሽኖች

  • Barometric pressure measurement
  • Barometric compensation of matric potential measurements
  • Digital/analog converter for directly connected TEROS 31 and TEROS 32 tensiometers
  • Appropriate for non-METER data loggers to connect TEROS 31 and TEROS 32

አድቫንTAGES

  • ዲጂታል ዳሳሽ በተከታታይ በይነገጽ ላይ ብዙ ልኬቶችን ያስተላልፋል
  • ዝቅተኛ-ግቤት ጥራዝtagሠ መስፈርቶች
  • አነስተኛ ኃይል ያለው ንድፍ በባትሪ የሚሰሩ ዳታ ሎጆችን ይደግፋል
  • SDI-12, Modbus RTU or tensio LINK serial communications protocol supported
  • Analog output supported (only 8-pin version)

SPECIFICATION

የመለኪያ ዝርዝሮች
ባሮሜትሪክ ግፊት
ክልል + 65 ኪፒኤ እስከ +105 ኪ.ፒ
ጥራት ± 0.0012 ኪ.ፒ
ትክክለኛነት ± 0.05 ኪ.ፓ
የሙቀት መጠን
ክልል -30 እስከ +60 ° ሴ
ጥራት ± 0.01 ° ሴ
ትክክለኛነት ± 0.5 ° ሴ
 የግንኙነት ዝርዝሮች
ውፅዓት
Analog Output (8-pin connector only)0 to 2,000 mV (default)0 to 1,000 mV (configurable with tensio VIEW)
Digital OutputSDI-12 communications protocol tensio LINK communication protocol Modbus RTU communication protocol
የውሂብ ሎገር ተኳኋኝነት
የአናሎግ ውፅዓት ከ3.6-28-VDC አበረታች እና ነጠላ ጫፍ ወይም ልዩነት ቮል መቀየር የሚችል ማንኛውም የመረጃ ማግኛ ስርዓትtagሠ ልኬት ከ12-ቢት ጥራት የበለጠ ወይም እኩል።
Digital Output Any data acquisition system capable of 3.6- to 28-VDC excitation and RS-485 Modbus or SDI-12 communication.
 አካላዊ መግለጫዎች
መጠኖች
ርዝመት 80 ሚሜ (3.15 ኢንች)
ስፋት 29 ሚሜ (1.14 ኢንች)
ቁመት 30 ሚሜ (1.18 ኢንች)
የኬብል ርዝመት
1.5 m (standard)NOTE: Contact Customer Support if a nonstandard cable length is needed.
የማገናኛ ዓይነቶች
4-pin and 8-pin M12 plug connector or stripped and tinned wires
 ተገዢነት
EM ISO/IEC 17050:2010 (CE Mark)

ተመጣጣኝ ዑደት እና የግንኙነት ዓይነቶች
Refer to Figure 2 to connect the BARO Module to a data logger. Figure 2 provides a low-impedance variant of the recommended SDI-12 specification.

METER-BARO-Module- (2)

METER-BARO-Module- (3)

METER-BARO-Module- (4)

ባሮ ሞዱል ኢንቴግሬተር መመሪያ METER-BARO-Module- (5)

METER-BARO-Module- (6)

METER-BARO-Module- (7)

METER-BARO-Module- (8)

ቅድመ ጥንቃቄዎች

የMETER ዳሳሾች የተገነቡት በከፍተኛ ደረጃዎች ነው፣ ነገር ግን አላግባብ መጠቀም፣ ተገቢ ያልሆነ ጥበቃ ወይም ተገቢ ያልሆነ ጭነት ሴንሰሩን ሊጎዳ እና ዋስትናውን ሊሽረው ይችላል። ዳሳሾችን ወደ ዳሳሽ አውታረመረብ ከማዋሃድዎ በፊት የሚመከሩትን የመጫኛ መመሪያዎችን ይከተሉ እና ዳሳሹን ከሚጎዳ ጣልቃገብነት ለመጠበቅ መከላከያዎችን ይተግብሩ።

ሴንሰር ኮሙኒኬሽን
METER digital sensors feature a serial interface with shared receive and transmit signals for communicating sensor measurements on the data wire. The sensor supports SDI-12, tensio LINK, and Modbus over RS-485 two-wire. The sensor automatically detects the interface and protocol which is being used. Each protocol has implementation advantages እና ፈተናዎች. ለሚፈለገው መተግበሪያ የፕሮቶኮል ምርጫ ግልጽ ካልሆነ እባክዎ የ METER ደንበኛ ድጋፍን ያግኙ።

  • SDI-12 መግቢያ
    SDI-12 ዳሳሾችን ከውሂብ ምዝግብ ማስታወሻዎች እና የውሂብ ማግኛ መሳሪያዎች ጋር ለማገናኘት በደረጃ ላይ የተመሰረተ ፕሮቶኮል ነው። ልዩ አድራሻ ያላቸው በርካታ ዳሳሾች አንድ የጋራ ባለ 3 ሽቦ አውቶቡስ (ኃይል፣ መሬት እና ውሂብ) ማጋራት ይችላሉ። በሴንሰሩ እና በሎገር መካከል ባለ ሁለት መንገድ ግንኙነት የሚቻለው በመደበኛው እንደተገለጸው ለማስተላለፍ እና ለመቀበል የመረጃ መስመርን በማጋራት ነው። የዳሳሽ መለኪያዎች የሚቀሰቀሱት በፕሮቶኮል ትእዛዝ ነው። የኤስዲአይ-12 ፕሮቶኮል በአውቶቡሱ ላይ ላለው ለእያንዳንዱ ሴንሰር ልዩ የሆነ የፊደል ቁጥራዊ ዳሳሽ አድራሻ ያስፈልገዋል ስለዚህ ዳታ ምዝግብ ማስታወሻ ደብተር ለመላክ እና ከተወሰኑ ሴንሰሮች ንባቦችን ይቀበላል።
    ስለ SDI-12 ፕሮቶኮል የበለጠ ለማወቅ SDI-1.3 Specification v12 አውርድ።
  • RS-485 መግቢያ
    RS-485 ብዙ መሳሪያዎችን ከአንድ አውቶቡስ ጋር ለማገናኘት ጠንካራ የሆነ አካላዊ የአውቶቡስ ግንኙነት ነው። በጣም ረጅም የኬብል ርቀቶችን በአስቸጋሪ አካባቢዎች ውስጥ መጠቀም ይችላል. ከSDI-12 ይልቅ፣ RS-485 ለመረጃ ምልክት ሁለት የወሰኑ ሽቦዎችን ይጠቀማል። ይህ ረዣዥም ኬብሎችን መጠቀም ያስችላል እና ምልክቱ ከተለያዩ ገመዶች ጋር ስለሚገናኝ እና የአቅርቦት ሞገዶች በመረጃ ምልክት ላይ ተጽዕኖ ስለሌለው ከውጭ ምንጮች ለሚመጡ ጣልቃገብነቶች የበለጠ ቸልተኛ ነው። በRS-485 ላይ ለበለጠ መረጃ ዊኪፔዲያን ይመልከቱ።
  • TENSIOLINK RS-485 መግቢያ
    tensioLINK በRS-485 በይነገጽ የሚገናኝ ፈጣን፣ አስተማማኝ፣ የባለቤትነት ተከታታይ የግንኙነት ፕሮቶኮል ነው። ይህ ፕሮቶኮል መረጃን ለማንበብ እና የመሳሪያውን ባህሪያት ለማዋቀር ይጠቅማል። METER የ tensioLINK ፒሲ ዩኤስቢ መቀየሪያ እና ሶፍትዌሮችን ከሴንሰሩ ጋር በቀጥታ ለመነጋገር፣ መረጃ ለማንበብ እና ፈርምዌርን ለማዘመን ያቀርባል። ስለ tensioLINK ተጨማሪ መረጃ ለማግኘት እባክዎ የደንበኛ ድጋፍ ሰጪን ያግኙ።
  • MODBUS RTU RS-485 መግቢያ
    Modbus RTU ከሁሉም አይነት ዲጂታል መሳሪያዎች ጋር ለመገናኘት በፕሮግራም ሎጅክ ተቆጣጣሪዎች (PLCs) ወይም በዳታ ሎጅገሮች የሚጠቀሙበት የተለመደ ተከታታይ የግንኙነት ፕሮቶኮል ነው። ግንኙነቱ በአካላዊ RS-485 ግንኙነት ላይ ይሰራል. የ RS-485 ለአካላዊ ግንኙነት እና Modbus እንደ ተከታታይ የግንኙነት ፕሮቶኮል ጥምረት ከአንድ ተከታታይ አውቶቡስ ሽቦ ጋር የተገናኙ ከፍተኛ ቁጥር ያላቸው ሴንሰሮች ፈጣን እና አስተማማኝ የውሂብ ማስተላለፍ ያስችላል። ለበለጠ የModbus መረጃ የሚከተሉትን ማገናኛዎች ተጠቀም፡ Wikipedia እና modbus.org።
  • ዳሳሹን ወደ ኮምፒዩተር ጣልቃ መግባት
    The serial signals and protocols supported by the sensor require some type of interface hardware to be compatible with the serial port found on most computers (or USB-to-serial adapters). There are several
    SDI-12 interface adapters available in the marketplace; however, METER has not tested any of these interfaces and cannot make a recommendation as to which adapters work with METER sensors. METER data loggers and the ZSC handheld device can operate as a computer-to-sensor interface for making on-demand sensor measurements.
    የ BARO ሞዱል እንዲሁ በ tensioLINK በኩል በ METER ሶፍትዌር tensio ሊዋቀር እና ሊለካ ይችላል።VIEW፣ በmeter.ly/software ላይ ለማውረድ ይገኛል። የ BARO ሞጁሉን ከኮምፒዩተር ጋር ለማገናኘት tensioLINK USB መለወጫ እና ተስማሚ አስማሚ ገመድ አስፈላጊ ነው.
  • METER SDI-12 ትግበራ
    የ BARO ሞዱል በ TEROS 31 ወይም 32 tensiometer መካከል ከተገናኘ፣ ሁለቱም የባሮሜትሪክ የአየር ግፊት እና የ TEROS tensiometer ፍፁም ግፊት በModbus በኩል ሊነበቡ ይችላሉ። የተከፈለው ማትሪክስ አቅም በModbus በኩልም ሊነበብ ይችላል።
    METER sensors use a low-impedance variant of the SDI-12 standard sensor circuit (Figure 2). During the power-up time, sensors output some sensor diagnostic information and should not be communicated with until the power-up time has passed. After the power up time, the sensors are fully compatible with all commands listed in the SDI-12 Specification v1.3 except for the continuous measurement commands ( aR0 – aR9 and aRC0 – aRC9 ). M , R , and C command implementations are found on pages 8–9. Out of the factory, all METER sensors start with SDI-12 address 0 .
  • ዳሳሽ አውቶቡስ ግምት
    SDI-12 sensor buses require regular checking, sensor upkeep, and sensor troubleshooting. If one sensor goes down, that may take down the whole bus even if the remaining sensors are functioning normally. Power cycling the SDI-12 bus when a sensor is failing is acceptable. METER SDI-12 sensors can be power-cycled and read on the desired measurement interval or powered continuously and commands sent when a measurement is desired based on specified communication timing. Many factors influence the effectiveness of the bus configuration. Visit metergroup.com ተጨማሪ መረጃ ለያዙ ጽሑፎች እና ምናባዊ ሴሚናሮች።

SDI-12 ውቅረት

ሠንጠረዥ 1 የ SDI-12 የግንኙነት ውቅር ይዘረዝራል።

ጠረጴዛ 1      SDI-12 የግንኙነት ውቅር
የባውድ ደረጃ 1,200
ቢትስ ጀምር 1
የውሂብ ቢት 7 (ኤልኤስቢ መጀመሪያ)
የአካል ክፍሎች 1 (እንኳን)
ቢቶችን ያቁሙ 1
አመክንዮ የተገለበጠ (ገቢር ዝቅተኛ)

SDI-12 ጊዜ
All SDI-12 commands and responses must adhere to the format in Figure 9 on the data line. Both the command and response are preceded by an address and terminated by a carriage return and line feed combination ( <CR><LF> ) and follow the timing shown in Figure 10.

METER-BARO-Module- (9)

METER-BARO-Module- (10)

የጋራ SDI-12 ትዕዛዞች
ይህ ክፍል በSDI-12 ስርዓት ውስጥ ብዙ ጊዜ ጥቅም ላይ የሚውሉ የ SDI-12 ትዕዛዞችን እና ከMETER ዳሳሾች የሚመጡ ተዛማጅ ምላሾችን ያካትታል።

የመታወቂያ ትእዛዝ (ኤአይ!)
የመለያ ትዕዛዙ ስለተገናኘው ዳሳሽ የተለያዩ ዝርዝር መረጃዎችን ለማግኘት ሊያገለግል ይችላል። አንድ የቀድሞampየትዕዛዙ እና ምላሹ በኤክስample 1, ትዕዛዙ በደማቅ ሲሆን ምላሹ ትዕዛዙን ይከተላል.

Example 1 1I!113METER␣ ␣ ␣BARO␣

መለኪያ

ቋሚ ባህሪ  ርዝመት  መግለጫ
 
1 እኔ! 3 Data logger command.Request to the sensor for information from sensor address 1 .
1 1 Sensor address.Prepended on all responses, this indicates which sensor on the bus is returning the following information.
13 2 የዒላማ ዳሳሽ SDI-12 Specification v1.3 ን እንደሚደግፍ ያሳያል።
METER ␣ ␣ ␣ 8 Vendor identification string.( METER and three spaces  ␣ ␣ ␣ for all METER sensors)
BARO␣ 6 Sensor model string.This string is specific to the sensor type. For the BARO, the string is BARO .
100 3 Sensor version.This number divided by 100 is the METER sensor version (e.g., 100 is version 1.00).
ባሮ-00001 ≤13,variable ዳሳሽ መለያ ቁጥር። ይህ ተለዋዋጭ ርዝመት መስክ ነው. ለቆዩ ዳሳሾች ሊቀር ይችላል።

የአድራሻ ትእዛዝ ለውጥ ( aAB! )
The Change Address command is used to change the sensor address to a new address. All other commands support the wildcard character as the target sensor address except for this command. All METER sensors have a default address of 0 (zero) out of the factory. Supported addresses are alphanumeric (i.e., A – Z , and 0 – 9 ). An exampከ METER ዳሳሽ የሚወጣው ውጤት በኤክስample 2, ትዕዛዙ በደማቅ ሲሆን ምላሹ ትዕዛዙን ይከተላል.

Example 2 1A0!0

 መለኪያ

ቋሚ ባህሪ  ርዝመት        መግለጫ
1A0! 4 Data logger command. Request to the sensor to change its address from 1 to a new address of 0 .
0 1 አዲስ ዳሳሽ አድራሻ። ለሁሉም ተከታይ ትዕዛዞች፣ ይህ አዲስ አድራሻ በዒላማ ዳሳሽ ጥቅም ላይ ይውላል።

የትእዛዝ ትግበራ
የሚከተሉት ሰንጠረዦች አስፈላጊ ሆኖ ሲገኝ ተገቢውን መለኪያ (M)፣ ቀጣይነት ያለው (አር) እና ተጓዳኝ (C) ትዕዛዞችን እና ቀጣይ የውሂብ (D) ትዕዛዞችን ይዘረዝራሉ።

የመለኪያ ትዕዛዞች ትግበራ
Measurement ( M ) commands are sent to a single sensor on the SDI-12 bus and require that subsequent Data ( D ) commands are sent to that sensor to retrieve the sensor output data before initiating communication with another sensor on the bus. Please refer to Table 2 and for an explanation of the command sequence and to Table 5 for an explanation of response parameters.

ጠረጴዛ 2 aM! የትእዛዝ ቅደም ተከተል

ትዕዛዝ ምላሽ
ይህ ትዕዛዝ አማካይ፣ የተጠራቀሙ ወይም ከፍተኛ እሴቶችን ያሳያል።
አኤም! atttn
ኤዲ0! ሀ ± ± +
አስተያየቶች When a slave TEROS tensiometer is connected, <Press> hold the barometric compensated tensiometer output. If the BARO module is used in standalone <Press> returns the current barometric pressure.
NOTE: The measurement and corresponding data commands are intended to be used back to back. After a measurement command is processed by the sensor, a service request a <CR><LF> is sent from the sensor signaling the measurement is ready. Either wait until   seconds have passed or wait until the service request is received before sending the data commands. See the SDI-12 Specifications v1.3

NOTE: The measurement and corresponding data commands are intended to be used back to back. After a measurement command is processed by the sensor, a service request a <CR><LF> is sent from the sensor signaling the measurement is ready. Either wait until ttt seconds have passed or wait until the service request is received before sending the data commands. See the SDI-12 Specifications v1.3 document for more information.

በአንድ ጊዜ የመለኪያ ትእዛዞች ትግበራ
የተጣጣመ መለኪያ (C) ትዕዛዞች በተለምዶ ከአውቶቡስ ጋር ከተገናኙ ዳሳሾች ጋር ጥቅም ላይ ይውላሉ. የ C ትዕዛዞች ለዚህ ዳሳሽ ከመደበኛው የC ትዕዛዝ ትግበራ ያፈነግጣሉ። በመጀመሪያ የ C ትዕዛዙን ይላኩ ፣ በ C ትዕዛዝ ምላሽ ውስጥ በዝርዝር የተገለጸውን የጊዜ መጠን ይጠብቁ ፣ እና ከሌላ ዳሳሽ ጋር ከመገናኘትዎ በፊት ምላሹን ለማንበብ D ትዕዛዞችን ይጠቀሙ።

Please refer to Table 3 for an explanation of the command sequence and to Table 5 for an explanation of response parameters.

Table 3      aC! measurement command sequence
ትዕዛዝ ምላሽ
ይህ ትዕዛዝ ቅጽበታዊ እሴቶችን ያሳያል።
አሲ! atttnn
ኤዲ0! ሀ ± ± +
NOTE: The measurement and corresponding data commands are intended to be used back to back. After a measurement commanc is pro- cessed by the sensor, a service request a<CR><LF> is sent from the sensor signaling the measurement is ready. Either wait until ttt sec- onds have passed or wait until the service request is received before sending the data commands. Please see the SDI-12 Specifications v1.3 document for more information.

NOTE: The measurement and corresponding data commands are intended to be used back to back. After a measurement commanc is pro-cessed by the sensor, a service request a<CR><LF> is sent from the sensor signaling the measurement is ready. Either wait until ttt sec-onds have passed or wait until the service request is received before sending the data commands. Please see the SDI-12 Specifications v1.3 document for more information.

ቀጣይነት ያለው የመለኪያ ትእዛዞች ትግበራ
Continuous Measurement ( R ) commands trigger a sensor measurement and return the data automatically after the readings are completed without needing to send a D command. aR0! returns more characters in its response than the 75-character limitation called out in the SDI-12 Specification v1.3. It is recommended to use a buffer that can store at least 116 characters.
Please refer to Table 4 for an explanation of the command sequence and see Table 5 for an explanation of response parameters.

Table 4      aR0! measurement command sequence
ትዕዛዝ ምላሽ
ይህ ትዕዛዝ አማካይ፣ የተጠራቀሙ ወይም ከፍተኛ እሴቶችን ያሳያል።
አር 0! ሀ ± ± +
ማሳሰቢያ፡ ይህ ትእዛዝ የ SDI-12 ምላሽ ጊዜን አያከብርም። ለበለጠ መረጃ METER SDI-12 ትግበራን ይመልከቱ።

NOTE: This command does not adhere to the SDI-12 response timing. See METER SDI-12 Implementation for more information.

ፓራሜትሮች
Table 5 lists the parameters, unit measurement, and a description of the parameters returned in command responses for the BARO Module.

ጠረጴዛ 5      የመለኪያ መግለጫዎች
መለኪያ ክፍል መግለጫ
± - የሚቀጥለውን እሴት የሚያመለክት አዎንታዊ ወይም አሉታዊ ምልክት
a - SDI-12 አድራሻ
n - የመለኪያዎች ብዛት (ቋሚ ወርድ 1)
nn - አስፈላጊ ከሆነ መሪ ዜሮ ያላቸው የልኬቶች ብዛት (ቋሚ የ 2 ስፋት)
ቲ.ቲ s ከፍተኛው ጊዜ መለካት ይወስዳል (ቋሚ 3 ስፋት)
- የትር ቁምፊ
- የመጓጓዣ መመለሻ ባህሪ
- የመስመር ምግብ ባህሪ
- ASCII character denoting the sensor type For BARO Module, the character is ;
- METER ተከታታይ ፍተሻ
- METER 6-ቢት CRC

ሜትር MODBUS RTU ተከታታይ ትግበራ
Modbus over Serial Line is specified in two versions – ASCII and RTU. BARO Modules communicate using RTU mode exclusively. The following explanation is always related to RTU. Table 6 lists the Modbus RTU communication and configuration.

ጠረጴዛ 6      Modbus communication characters
የባውድ መጠን (ቢፒኤስ) 9,600 ቢፒኤስ
ቢትስ ጀምር 1
የውሂብ ቢት 8 (ኤልኤስቢ መጀመሪያ)
የአካል ክፍሎች 0 (ምንም)
ቢቶችን ያቁሙ 1
አመክንዮ መደበኛ (ንቁ ከፍተኛ)

METER-BARO-Module- (10)Figure 11 shows a message in RTU format. The size of the data determines the length of the message. The format of each byte in the message has 10 bits, including Start and Stop Bit. Each byte is sent from left to right: Least Significant Bit (LSB) to Most Significant Bit (MBS). If no parity is implemented, an additional stop bit is transmitted to fill out the character frame to a full 11-bit asynchronous character.

The Modbus application layer implements a set of standard Function codes divided into three categories: Public, User-defined, and Reserved. Well-defined public function codes for BARO Modules are documented in the Modbus Organization, Inc. (modbus.org) community.

For a reliable interaction between the BARO Module and a Modbus Master, a minimum 50ms delay is required between every Modbus command sent on the RS-485 bus. An additional timeout is needed for every Modbus query; this timeout is device-specific and depends on the quantity of the polled registers. Generally, 100ms will work fine for most of the BARO Module.

የሚደገፉ MODBUS ተግባራት

Table 7 Function Definitions

ተግባር ኮድ ድርጊት መግለጫ
01 የኮይል/ወደብ ሁኔታን አንብብ በModBusSlave ውስጥ የልዩ ውፅዓት(ዎች) ማብራት/ማጥፋት ሁኔታን ያነባል።
02 የግቤት ሁኔታ አንብብ በModBusSlave ውስጥ የልዩ ግብዓት(ዎች) ማብራት/ማጥፋት ሁኔታን ያነባል።
03 የመያዣ መዝገቦችን ያንብቡ በModBusSlave ውስጥ መመዝገቢያ(ዎች)ን የመያዣ ሁለትዮሽ ይዘቶችን ያነባል።
04 የግቤት መዝገቦችን ያንብቡ በModBusSlave ውስጥ የግቤት መመዝገቢያ(ዎች) ሁለትዮሽ ይዘቶችን ያነባል።
05 ነጠላ ጥቅልል/ወደብ አስገድድ በModBusSlave ውስጥ አንድ ነጠላ ጥቅልል/ወደብ ለማብራት ወይም ለማጥፋት ያስገድዳል
06 ነጠላ መዝገብ ይጻፉ በModBusSlave ውስጥ እሴትን ወደ መያዣ መዝገብ ይጽፋል
15 Force multiple coils/ports Forces multiple coils/ports in the ModBusSlave to either on or off
16 ብዙ መዝገቦችን ይፃፉ Writes values into a series of holding registers in the ModBusSlave

የውሂብ ውክልና እና ሰንጠረዦች መመዝገብ
Data values (setpoint values, parameters, sensor-specific measurement values, etc.) sent to and from the BARO Module use 16-bit and 32-bit holding (or input) registers with a 4-digit address notation. The address spaces are virtually distributed in different blocks for each data type. This is an approach to the Modbus Enron implementation. Table 8 shows the four main tables used by the BARO Module with their respective access rights. Table 9 describes the sub-blocks for each different data type representation.

እባክዎ አንዳንድ የModbus ዳታሎገሮች አድራሻን በ+1 ማካካሻ እንደሚጠቀሙ ልብ ይበሉ። ይህ አንዳንድ ጊዜ ግራ መጋባትን ይፈጥራል እና በModbus ዝርዝር ባዶነት ላይ የተመሰረተ ነው። የእርስዎን Modbus ፕሮግራም በዳታሎገር ላይ በመተግበር ላይ ችግሮች ካሉ ሁል ጊዜ የተለያዩ የመመዝገቢያ ማካካሻዎችን እና የውሂብ አይነቶችን ይሞክሩ። የሚታወቅ ዋጋን መጠቀም፣ ልክ እንደ ሙቀት፣ ምን ዋጋ እንደሚጠብቀው በሚታወቅበት ቦታ መሞከር ለመጀመር ጥሩ ልምምድ ነው።

Table 8      Modbus Primary Tables
የመመዝገቢያ ቁጥር የጠረጴዛ ዓይነት መዳረሻ መግለጫ
1xxx የተለየ የውጤት መጠምጠሚያዎች አንብብ/ጻፍ on/off status or setup flags for the sensor
2xxx የተለየ የግቤት እውቂያዎች አንብብ ዳሳሽ ሁኔታ ባንዲራዎች
3xxx የአናሎግ ግቤት መመዝገቢያዎች አንብብ የቁጥር ግቤት ተለዋዋጮች ከዳሳሽ (ትክክለኛ ዳሳሽ መለኪያዎች)
4xxx የአናሎግ ውፅዓት መያዣ መመዝገቢያዎች አንብብ/ጻፍ ለአነፍናፊው የቁጥር ውፅዓት ተለዋዋጮች (መለኪያዎች ፣ የነጥብ እሴቶች ፣ መለኪያዎች ወዘተ)

ለ example, register 3001 is the first analog input register (first data address for the input registers). The numeric value stored here would be a 16-bit unsigned integer-type variable that represents the first sensor measurement parameter (pressure value). The same measurement parameter (pressure value) could be read at register 3201, but this time as a 32-bit floating-point value with a Big-Endian format. If the Modbus Master (Datalogger or a PLC) supports only 32-bit float-values with a Little-Endian format, then one could read the same measurement parameter (same pressure value) at register 3301. The Virtual Sub-Blocks are meant to simplify the user’s effort in programming the Modbus query of the sensors.

ጠረጴዛ 9      Modbus Virtual Sub-Blocks
የመመዝገቢያ ቁጥር መዳረሻ መጠን Sub-Table ውሂብ ዓይነት
X001-X099 አንብብ/ጻፍ 16 ቢት የተፈረመ ኢንቲጀር
X101-X199 አንብብ/ጻፍ 16 ቢት ያልተፈረመ ኢንቲጀር
X201-X299 አንብብ/ጻፍ 32 ቢት float Big-Endian format
X301-X399 አንብብ/ጻፍ 32 ቢት float Little-Endian format

ካርታ መስራት ይመዝገቡ

ጠረጴዛ 10      መዝገቦችን በመያዝ ላይ
41000 (41001*) የሞድቡስ ባሪያ አድራሻ
ዝርዝር መግለጫ Read or update the sensor’s modbus address
የውሂብ አይነት ያልተፈረመ ኢንቲጀር
የተፈቀደ ክልል 1 - 247
ክፍል
አስተያየቶች Updated slave address will be stored in the sensor’s nonvolatile memory

ጠረጴዛ 11      BARO Module Input Registers
32000 (32001*) Soil Water Potential
ዝርዝር መግለጫ Compensated tension value from tensiometer
የውሂብ አይነት 32 bit floating Big-Endian
የተፈቀደ ክልል -200 እስከ +200
ክፍል ኪፓ
አስተያየቶች Tensiometer needs to be connected as slave
32001 (32002*) የአፈር ሙቀት
ዝርዝር መግለጫ High accuracy on board temperature measurement
የውሂብ አይነት 32 bit floating Big-Endian
የተፈቀደ ክልል -30 እስከ +60
ክፍል ድ.ግ.
አስተያየቶች Tensiometer needs to be connected as slave
32002 (32003*) ዳሳሽ አቅርቦት ጥራዝtage
ዝርዝር መግለጫ On board supply voltagሠ መለካት
የውሂብ አይነት 32 bit floating Big-Endian
የተፈቀደ ክልል -10 እስከ +60
ክፍል ቮልት
አስተያየቶች
32003 (32004*) ባሮ ሁኔታ
ዝርዝር መግለጫ Binary status
የውሂብ አይነት 32 bit floating Big-Endian
የተፈቀደ ክልል 0/1
ክፍል
አስተያየቶች
32004 (32005*) BARO Reference Pressure
ዝርዝር መግለጫ On board high accuracy barometric pressure measurement
የውሂብ አይነት 32 bit floating Big-Endian
የተፈቀደ ክልል ከ +70 እስከ +120
ክፍል ኪፓ
አስተያየቶች
ሠንጠረዥ 11 ባሮ ሞዱል የግቤት መመዝገቢያዎች (የቀጠለ)
32005 (32006*) ቴንስዮሜትር ጫና
ዝርዝር መግለጫ Absolute pressure value from tensiometer
የውሂብ አይነት 32 bit floating Big-Endian
የተፈቀደ ክልል -200 እስከ +200
ክፍል ኪፓ
አስተያየቶች Tensiometer needs to be connected as slave
32006 (32007*) ባሮ የሙቀት መጠን
ዝርዝር መግለጫ On board temperature measurement
የውሂብ አይነት 32 bit floating Big-Endian
የተፈቀደ ክልል -30 እስከ +60
ክፍል ድ.ግ.
አስተያየቶች

*አንዳንድ መሳሪያዎች የModbus መመዝገቢያ አድራሻዎችን በ+1 ማካካሻ ሪፖርት ያደርጋሉ። ይህ ለሲampደወል ሳይንቲፊክ ሎገሮች እና ዳታከር ሎገሮች። የተፈለገውን መዝገብ ለማንበብ በቅንፍ ውስጥ ያለውን ቁጥር ይጠቀሙ.

EXAMPLE አንድ CR6 ዳታሎግገር እና MODBUS RTU መጠቀም
ሲampbell Scientific, Inc. CR6 Measurement and Control Datalogger supports Modbus master and Modbus slave communication to integrate Modbus SCADA networks. The Modbus communications protocol facilitates the exchange of information and data between a computer/HMI software, instruments (RTUs), and Modbus-compatible sensors. The CR6 datalogger communicates exclusively in RTU mode. In a Modbus network, each slave device has a unique address. Therefore, sensor devices must be configured correctly before connecting to a Modbus Network. Addresses range from 1 to 247. Address 0 is reserved for universal broadcasts.

CR6 ዳታሎግገርን በማዘጋጀት ላይ
በCR6 (እና CR1000) ሎገሮች ላይ የሚሰሩ ፕሮግራሞች የተፃፉት በ CRBasic፣ በ C በተዘጋጀ ቋንቋ ነው።ampደወል ሳይንሳዊ. ዳታ ሎጅ እንዴት እና መቼ መለኪያዎችን እንደሚወስድ፣ ውሂብን እንደሚያስኬድ እና እንደሚግባባ ለማስተማር ቀላል ግን እጅግ ተለዋዋጭ እና ኃይለኛ ዘዴ ለማቅረብ የተነደፈ ከፍተኛ ደረጃ ቋንቋ ነው። ፕሮግራሞች የShortCut ሶፍትዌርን በመጠቀም ወይም የCRBasic Editorን በመጠቀም ሊፈጠሩ ይችላሉ፣ ሁለቱም እንደ ገለልተኛ አፕሊኬሽኖች በይፋዊው ሲ ላይ ለማውረድ ይገኛሉ።ampደወል ሳይንሳዊ webጣቢያ (ኦampbellsci.com). ShortCut Software (https://www.campbellsci.com/shortcut) CRBasic Editor (https://www.campbellsci.com/crbasiceditor)

A typical CRBasic program for a Modbus application consists of the following:

  • Variables and constants declarations (public or private)
  • Units declarations
  • የውቅረት መለኪያዎች
  • Data tables declarations
  • Logger Initializations
  • Scan (Main Loop) with all the sensors to be quired
  • Function call to the Data Tables

CR6 LOGGER RS-485 CONNECTION INTERFACE
የCR6 ሁለንተናዊ (U) ተርሚናል ከማንኛውም ሴንሰር አይነት ጋር የሚገናኙ 12 ቻናሎችን ያቀርባል። ለ CR6 ተጨማሪ አፕሊኬሽኖችን የማዛመድ ችሎታ ይሰጠዋል እና ብዙ ውጫዊ ተጓዳኝዎችን መጠቀምን ያስወግዳል።
በስእል 12 ላይ የሚታየው Modbus CR6 ግንኙነት በተርሚናሎች (C1-C2) እና (C3-C4) ላይ የተገጠመውን የRS-485 (A/B) በይነገጽ ይጠቀማል። እነዚህ መገናኛዎች በግማሽ-ዱፕሌክስ እና ሙሉ-ዱፕሌክስ ውስጥ ሊሠሩ ይችላሉ። ለዚህ የቀድሞ ጥቅም ላይ የዋለው የባሮ ሞዱል ተከታታይ በይነገጽample ከ (C1-C2) ተርሚናሎች ጋር ተያይዟል።

BARO ሞዱል ወደ CR6 ዳታሎገር ሽቦ ዲያግራም።METER-BARO-Module- (12)

After assigning the BARO Module a unique Modbus Slave Address, it can be wired to the CR6 logger according to Figure 12. Make sure to connect the white and black wires according to their signals, respectively, to the C1 and C2 ports—the brown wire to 12V (V+) and the blue to G (GND). To control the power supply through your program, connect the brown wire directly to one of the SW12 terminals (switched 12V outputs).

EXAMPLE ፕሮግራሞች

METER-BARO-Module- (13) METER-BARO-Module- (14) METER-BARO-Module- (15)

የደንበኛ ድጋፍ

ሰሜን አሜሪካ
የደንበኞች አገልግሎት ተወካዮች ከሰኞ እስከ አርብ ከጠዋቱ 7፡00 እስከ 5፡00 ፒኤም በፓሲፊክ ሰዓት ለጥያቄዎች፣ ለችግሮች ወይም ለአስተያየቶች ይገኛሉ።

አውሮፓ

METERን በኢሜል ካነጋገሩ፣ እባክዎ የሚከተለውን መረጃ ያካትቱ፡

  • ስም
  • አድራሻ
  • ስልክ ቁጥር
  • የኢሜል አድራሻ
  • የመሳሪያ መለያ ቁጥር

የችግር መግለጫ

ማስታወሻ፡- በአከፋፋይ በኩል ለተገዙ ምርቶች፣ እባክዎን እርዳታ ለማግኘት አከፋፋዩን በቀጥታ ያግኙ።

የክለሳ ታሪክ
የሚከተለው ሠንጠረዥ የሰነድ ክለሳዎችን ይዘረዝራል።

ክለሳ ቀን ተኳሃኝ Firmware መግለጫ
00 6.2025 1.10 የመጀመሪያ ልቀት

የሚጠየቁ ጥያቄዎች

What should I do if I need a nonstandard cable length?

Contact Customer Support for assistance with nonstandard cable lengths.

How do I know which communication protocol to use for my application?

Evaluate the advantages and challenges of each protocol based on your application needs. If unsure, contact METER Customer Support for guidance.

ሰነዶች / መርጃዎች

METER BARO ሞዱል [pdf] የተጠቃሚ መመሪያ
TEROS 31፣ TEROS 32፣ BARO Module፣ BARO Module፣ Module

ዋቢዎች

አስተያየት ይስጡ

የኢሜል አድራሻዎ አይታተምም። አስፈላጊ መስኮች ምልክት ተደርጎባቸዋል *